Seated / Landed signal adjustment
1 Check that the SEATED PIN can move up and down freely. The force needed to lift
the pin is approx. 10 kg (20 lbs).
2 The SEATED signal should switch on with the pin protruding approx. 9 mm below
the landing surface of the end beam.
3 If adjustment of the proximity switch / sensor is necessary, remove the seated
sensor mounting bracket incl. sensor from the top of the seated tower, and adjust
the proximity switch / sensor so that the end surface is 7-8 mm above the lower
mounting surface of the bracket. This adjustment will result in the seated pin
indication being switched on when the underside of the seated pin is approx. 8 to
10 mm lower than the end beams landing surface. This adjustment also ensures
that the mechanical and electrical lockout is released so that the twistlocks can
be turned.