4.

 

Remove the +ve power supply from the control panel and check internal battery voltage is greater than 4.5v dc. If the 
battery voltage is less than this value, the battery must be replaced. See ‘Specifications’ section for replacement battery 
details. 

5.

 

Check for signs of significant water or insect ingress. Clean as necessary. 

 

D

IAGNOSTICS

 

 

NOTE: Commissioning Mode only activated when ENG is connected to 9-15vdc AND 5s Time-out selected 

Commissioning 

Tones 

Status Indicated 

Action 

Single Click 

Tamper closing – front or rear 

Use to ensure that the rear tamper has been fully closed 
or that the cover has been fully closed. 

Double Click 

Tamper opening – front or rear 

Use to verify correct operation of tamper circuit 

Continuous slow clicks 

Rear tamper not closed when cover tamper 
is closed 

Check tamper insert is not detached from backplate 

Continuous fast clicks 

Battery not connected or faulty when cover 
tamper is closed 

Open cover and check that battery is correctly 
connected. 

 

F

AULT 

F

INDING

 

 

 

Symptom 

Fault 

Action 

Sounder activated in 
non-alarm condition 
and tamper at panel 

Cover not closed correctly. 

Check cover closed and screw secure. 

Rear tamper insert disengaged from backplate 

Check tamper insert is not detached from 
backplate 

Sounder activated in 
non-alarm condition 
and NO tamper at panel 

R- not pulled up to +12V in standby mode 

Fit ‘pull up’ resistor to R- at control panel, 
see Note 1 (Fig. 2 & Fig. 3) 

Sounder stops after 5s 

Incorrect timer link setting 

Set correct timer jumper links. 

Cannot SET control 
panel 

(due to sounder 
tamper) 

Tamper output open due to ENG input still connected 
to H+ 

Disconnect ENG from H+ in sounder or set 
control panel programmable output low. 

Tamper Source (TS) not connected to H- for single 
sounder or to Tamper Return (TR) for cascaded 
sounders 

Refer to connection diagrams for cascaded 
sounders (Figure 3). 

Cover or Rear tamper switch not closed. 

Check cover and rear tamper switches closed. 

Total resistance of tamper circuit is too high for 
multiple sounder installations 

Reduce number of cascaded sounders on one 
tamper loop 

Fault output open 

Battery not connected 

Check battery connections to terminal block. 

Battery faulty or low voltage 

Replace battery. 

Piezo fault 

Return unit to manufacturer 

Battery charger faulty 

 

 

 

 

             

 

 

          

Содержание VERTEC-3000-G3

Страница 1: ...h fault output Remote test input facility Selectable sound auto cut off timer no cut off 5s for test 3 10 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash...

Страница 2: ...CTIONAL INFORMATION Tamper Circuit for Single or Multiple Cascade Installations For a single siren installation link TS to H and connect TR to the control panel Tamper return input In cascade installa...

Страница 3: ...pproximately 1Hz SAB Mode In SAB mode the sounder can draw current from both the control panel and the battery The siren will self activate if either of the tampers are activated In SCB mode the sound...

Страница 4: ...strobe Trigger and Supply BAT Negative battery connection Connect black battery lead after applying power Panel First Only unit Last unit Furthest from panel 0V Strobe Trigger Fault i p Fault i p 12V...

Страница 5: ...rol panel bell and strobe outputs are switched off Remove cover and check sounder operates due to top tamper 4 If a Tamper Return connection is made to the control panel check that the panel detects a...

Страница 6: ...rectly connected FAULT FINDING Symptom Fault Action Sounder activated in non alarm condition and tamper at panel Cover not closed correctly Check cover closed and screw secure Rear tamper insert disen...

Страница 7: ...s DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002 96 EC Waste Electrical and Electronic Equipment WEEE and 2006 66 CE Battery At the end of life the produc...

Страница 8: ...urrent rating Sound Trigger Input R 3 5Vdc sound ON R 8 5Vdc sound OFF 12mA max Strobe Trigger Input ST 6 5Vdc strobe flash ON ST 6 6Vdc strobe OFF 5mA max Fixings No 10 M5 self tapping screws 4 off C...

Отзывы: