Technical Support Line +44 (0)23 9269 6638 (Option 3) 

PAK200218 Iss 05B  Oct 2012 

©2012 ELMDENE INTERNATIONAL LTD 

 
 
 
 
 
 
 
 
 
 

VERTEC-3000-G3                             External Grade 3 Sounder

 

 

F

EATURES 

 

 

 

-

 

105dB(A) siren output 

-

 

12v dc voltage operation 

-

 

Integral 1.0 Watt Xenon tube strobe (with 

active inrush current limit) 

-

 

3 way tamper protection: cover, rear & module 

-

 

Separate sound and strobe trigger inputs 

-

 

Hold-off supply failure detection 

-

 

Battery and piezo test with fault output 

-

 

Remote test input facility 

-

 

Selectable sound auto cut-off timer:  no cut-off, 
5s (for test), 3, 10, 15 minutes 

-

 

Full SAB using internal battery 

-

 

Twin Comfort LEDs selectable on, off, alternate 
flash 

-

 

4 selectable sound tones 

-

 

Audible Tamper to assist commissioning 

-

 

Ring Line Monitoring 

-

 

Fully enclosed electronics module 

-

 

Engineer Mode for quiet installation and 
maintenance 

-

 

Polycarbonate cover and backplate 

-

 

Microprocessor controlled 

         

 

    

 

 

              

 

Elmdene International Ltd

 

 

Tel:  +44(0)23 9269 6638 

3 Keel Close, Interchange Park, 

 

Fax:  +44(0)23 9266 0483 

Portsmouth, Hampshire, PO3 5QD, UK 

Web:   

www.elmdene.co.uk

 

Figure 1: Vertec 3000 Module 

Содержание VERTEC-3000-G3

Страница 1: ...h fault output Remote test input facility Selectable sound auto cut off timer no cut off 5s for test 3 10 15 minutes Full SAB using internal battery Twin Comfort LEDs selectable on off alternate flash...

Страница 2: ...CTIONAL INFORMATION Tamper Circuit for Single or Multiple Cascade Installations For a single siren installation link TS to H and connect TR to the control panel Tamper return input In cascade installa...

Страница 3: ...pproximately 1Hz SAB Mode In SAB mode the sounder can draw current from both the control panel and the battery The siren will self activate if either of the tampers are activated In SCB mode the sound...

Страница 4: ...strobe Trigger and Supply BAT Negative battery connection Connect black battery lead after applying power Panel First Only unit Last unit Furthest from panel 0V Strobe Trigger Fault i p Fault i p 12V...

Страница 5: ...rol panel bell and strobe outputs are switched off Remove cover and check sounder operates due to top tamper 4 If a Tamper Return connection is made to the control panel check that the panel detects a...

Страница 6: ...rectly connected FAULT FINDING Symptom Fault Action Sounder activated in non alarm condition and tamper at panel Cover not closed correctly Check cover closed and screw secure Rear tamper insert disen...

Страница 7: ...s DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2002 96 EC Waste Electrical and Electronic Equipment WEEE and 2006 66 CE Battery At the end of life the produc...

Страница 8: ...urrent rating Sound Trigger Input R 3 5Vdc sound ON R 8 5Vdc sound OFF 12mA max Strobe Trigger Input ST 6 5Vdc strobe flash ON ST 6 6Vdc strobe OFF 5mA max Fixings No 10 M5 self tapping screws 4 off C...

Отзывы: