background image

 

 

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

 

PAK200609_01F   Jan 2021                      ©2019 ELMDENE INTERNATIONAL LTD  

 

C

OMPLIANCE

 

 

 
This power supply unit meets the essential requirements of the  
following EU Directives: 
 

 

 
 
 
 

 
 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 
This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EC  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 
Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries 
safely for onward transport to your supplier, collection point or disposal facility. 
 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 
See  Specification  for  battery  type  information.  The  battery  is  marked  with  the  crossed  out  wheelie  bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 
 

For more information see: 

www.recyclethis.info

 

 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly. 

 

 
 

 

EMC: 

2014/30/EU

 

Low Voltage: 

2014/35/EU 

WEEE: 

2012/19/EU 

RoHS: 

2011/65/EU 

0843 14 (UL) 

2531 20 (DBI)

 

Elmdene International Ltd 3 Keel 

Close Portsmouth PO35QD 

0843-CPR-0215 

2531-CPR-CSP11214 

EN54-4:1997 +A1 +A2 

Power Supplies intended for use in 

fire detection and fire alarm 

systems 

 

Operational reliability

                    

- Pass 

 

Durability 

 

 

 

Temperature resistance  

Pass 

Vibration resistance 

Pass 

Electrical stability 

Pass 

Humidity resistance 

Pass 

 
 

Содержание STX2405-MOD

Страница 1: ...ents premature battery failure when operating from standby for extended periods Two sets of volt free solid state relay fault output signal i loss of mains and ii battery fault charger fault and loss...

Страница 2: ...5 0A 5 0 A 5 0A 5 0 A Battery Capacity eg PowerSonic model Yuasa model Interlogix model 2 x 2 1Ah 12V PS12021 NP2 1 12 2 x 7Ah 12V PS12070 NP7 12 2 x 17Ah 12V PS12170 NP17 12 BS131N Battery Charging C...

Страница 3: ...ault GEN Fault Condition Possible Cause Action CLOSED CLOSED Normal operation Mains present Battery healthy None OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mains CLOS...

Страница 4: ...ctive Battery charging normally but 90 of full charge None 2 PULSES ON No Battery Battery disconnected Battery fuse blown Battery heavily discharged Check battery connections Check battery fuse Check...

Страница 5: ...s less than 60V dc Cable Sizing 1 Mains input cable must be to the applicable standard with a 5A or greater current capacity i e 0 75 mm2 nominal conductor area having a minimum operating voltage of 3...

Страница 6: ...Figure 3 Terminal labels Standby Batteries 10 With mains disconnected connect the two 12V standby batteries in series using the single cable provided Connect the negative of one battery to the positiv...

Страница 7: ...contact NOTE Batteries must be connected before mains power is applied to enable the batteries to be utilised When replacing batteries re connect new batteries and then cycle the mains power OPERATING...

Страница 8: ...l regulations Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution Risk of fire or explosion if bare battery wires are allowed to touch See...