background image

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

  PAK200545_03B May 2016                        ©2016 ELMDENE INTERNATIONAL LTD  

 

Tamper 

19)

 

Connect tamper switch to appropriate inputs of control and indicating equipment (CIE). 

 
 

 

Fig 7  Position of tamper assembly on ‘hinged lid’ style enclosures 

 
 
 
 
 

 

 

Fig 8  Position of tamper assembly on ‘clam shell’ style enclosures 

 
20)

 

Close the lid and fasten with screw supplied. Alternatively fit the cover in place, the correct orientation 
is with the cover retaining feature engaging over the bottom lip of the base, fasten with screws 
supplied.  

21)

 

Check that the tamper switch is: 

CLOSED when the lid/cover is closed and the retaining screws are fitted. 
OPEN when the retaining screws are removed the lid/cover is open. 
Use fine adjustment screw if necessary to align set position indicator with set point. 

22)

 

Close the lid/cover and fasten. 

23)

 

Re-check tamper circuit is closed at control panel. 

Tamper Switch Connections 

Set position indicator 

Fine adjustment screw 

Lid Fixing Screw 
(Sets tamper switch) 

Lid Fixing Screw 

(Sets tamper switch) 

Tamper switch Connections 

Fine adjustment screw 

Set position indicator 

Содержание GEN2-08 Series

Страница 1: ...a false loss of mains alarm Two LEDs assist with quick and easy installation by showing presence of mains correct battery charging and a fault condition Comprehensive protection is built in as standar...

Страница 2: ...x 200 x 80 355 x 330 x 80 330x 275 x 80 Weight kg excluding battery 2 0 4 0 3 3 Material 1 2mm steel white powder coated Environmental Temperature 10 to 40 C operating 75 RH non condensing 20 to 80 C...

Страница 3: ...mains fail Open if loss of mains GEN Fault Relay output for General Fault Open in fault condition BATT Connection to standby battery Use cables provided Observe polarity INSTALLATION AND COMMISSIONING...

Страница 4: ...rectly rated load cable through supplied ferrite 1 turn and attach to terminal block note polarity Fasten with cable ties Fig 2 Position of ferrite 9 Apply mains power Check Green Mains LED is ON NOTE...

Страница 5: ...ntinue to supply voltage and current to the output load Check that Green Mains LED is OFF and the control panel displays a Loss of Mains EPS fault NOTE Batteries must have sufficient charge to supply...

Страница 6: ...er retaining feature engaging over the bottom lip of the base fasten with screws supplied 21 Check that the tamper switch is CLOSED when the lid cover is closed and the retaining screws are fitted OPE...

Страница 7: ...E parts inside There is no regular maintenance required of the PSU other than periodic testing and replacement of the standby battery Reference should be made to the battery manufacturer s documentati...

Страница 8: ...WEEE and 2013 56 EU Battery At the end of life the product must be separated from the domestic waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national...

Отзывы: