13.8Vdc Switch Mode Power Supply 

GEN2-08-y

#  

for 8Ah Battery and up to 1.0A* Continuous Load Current 

GEN2-18-y

#

 

for 18Ah Battery and up to 1.5A* Continuous Load Current

 

 
 

F

EATURES

 

 

 
 
High  efficiency  cost  effective  power  supply  suitable  for  use  in  systems  designed  to  comply  with 
PD6662:2010 and EN50131-6:2008 Grade 2 and Environmental Class II requiring 8Ah or 18Ah standby 
battery  capacity.  Two  independent  output  signals  are  provided  for  loss  of  mains  fault  (EPS**),  and 
general fault (including APS** fault). Self-diagnostics can detect blown output and battery fuses and 
low battery voltage (APS fault). The PSU incorporates a battery management system comprising low 
battery voltage detection and deep discharge protection to ensure that the battery is not permanently 
damaged through excessive discharge. A brownout filter ensures that short mains voltage dips do not 
create  a  false  loss  of  mains  alarm.  Two  LEDs  assist  with  quick  and  easy  installation  by  showing 
presence of mains, correct battery charging and a fault condition. Comprehensive protection is built-in 
as standard including mains transient filtering, electronic output overload protection and fuses on the 
load and battery outputs. 
 
 

 

PD6662:2010 and EN50131-6:2008 

Type A, Security Grade 2 
Environmental Class II Compliant 

 

Low quiescent battery monitoring current during standby operation 

 

Fault signals for loss of mains, power supply fault, and battery low voltage warning 

 

Battery Deep Discharge Protection 

 

Protection against reverse battery connection 

 

LED for comprehensive diagnostics 

 

Thermal protection of power circuitry 

 

Mains transient suppression and brown-out filter 

 

Fully enclosed lid tamper circuit 

 
 
 

#

     “y” Denotes enclosure size – see overleaf 

*     See table overleaf to determine continuous standby battery current available for given standby times 
**   EN50131 Definitions:  

EPS = External Power Source 

APS = Alternative Power Source 

 

              

 

Elmdene International Ltd

 

 

Tel:  +44(0)23 9269 6638 

3 Keel Close, Interchange Park, 

 

Fax:  +44(0)23 9266 0483 

Portsmouth, Hampshire, PO3 5QD, UK 

Web:   

www.elmdene.co.uk

 

Содержание GEN2-08 Series

Страница 1: ...a false loss of mains alarm Two LEDs assist with quick and easy installation by showing presence of mains correct battery charging and a fault condition Comprehensive protection is built in as standar...

Страница 2: ...x 200 x 80 355 x 330 x 80 330x 275 x 80 Weight kg excluding battery 2 0 4 0 3 3 Material 1 2mm steel white powder coated Environmental Temperature 10 to 40 C operating 75 RH non condensing 20 to 80 C...

Страница 3: ...mains fail Open if loss of mains GEN Fault Relay output for General Fault Open in fault condition BATT Connection to standby battery Use cables provided Observe polarity INSTALLATION AND COMMISSIONING...

Страница 4: ...rectly rated load cable through supplied ferrite 1 turn and attach to terminal block note polarity Fasten with cable ties Fig 2 Position of ferrite 9 Apply mains power Check Green Mains LED is ON NOTE...

Страница 5: ...ntinue to supply voltage and current to the output load Check that Green Mains LED is OFF and the control panel displays a Loss of Mains EPS fault NOTE Batteries must have sufficient charge to supply...

Страница 6: ...er retaining feature engaging over the bottom lip of the base fasten with screws supplied 21 Check that the tamper switch is CLOSED when the lid cover is closed and the retaining screws are fitted OPE...

Страница 7: ...E parts inside There is no regular maintenance required of the PSU other than periodic testing and replacement of the standby battery Reference should be made to the battery manufacturer s documentati...

Страница 8: ...WEEE and 2013 56 EU Battery At the end of life the product must be separated from the domestic waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national...

Отзывы: