background image

ELM-PA-G3-X Panic Button Guide

Specifications

Contact

Power Handling

10VA

Voltage Rating

30Vdc

Current Rating

1.0A Max

Resistance

<300mohms

Operating Life

>1 x 10 operations

8

Temperature Range

-10

Dimensions

62 x 80 x 27mm

°C to+40°C

X is colour code:

ELM-PA-G3-W White, ELM-PA-G3-B Brass, ELM-PA-G3-SS Steel

ELM-PA-G3-BK Black

2015 Elmdene International Ltd

PAK200464 Feb 2015 Iss 03C

Page 1

Technical Support Line + 44 (0) 2392 696638

Setting reed - Normally Open (N.O.) or Normally Closed (N.C.)

Default is set to Normally closed. Please skip this section if this is the required setting.

1.

Tab

Tab

Follow steps 1&2 in reverse order to re-assemble. Take care not to damage the reed switch.

Wall Mounting

1. Press both buttons to move mechanism out of the way and gain access to the bottom fixing hole.
2. Mark positions of holes on the wall.
3. Drill holes to required depth and use appropriate wall plugs or fixings (No. 6 / 5mm).
4. Drive bottom

screw through base and into wall.

5. Insert top

screw through PCB and plastic and screw into wall.

6.

7. Angle lid as shown above. Slide upward

pushing lid closed. Fasten lid shut with screw.

countersunk

pan head

before

Take care not to snap

the PCB tamper breakout.

Use friction adjustment screw to ensure sliding mechanism does not move without being pushed

by buttons or reset key.

DO NOT OVERTIGHTEN

Use of the PA button

Correct Use of PA Buttons

1. Push both buttons together to operate. After use

indicator will be red (latched).

2. To reset insert the key into the slot as shown.
3. Turn key clockwise as far as it will turn (about 120

degrees) to reset the PA.

4. Turn the key anticlockwise back to the start and remove it.
5. Indicator will now be yellow (ready).

PA buttons should be installed in accordance with any applicable
regulations relating to panic alarms. Potential users should be advised in
the use of the PA.

Page 2

Top mounting
screw hole

Bottom mounting
screw hole

2.

3.

Friction
Adjustment
Screw

Normally Closed
(Factory Default)

Normally
Open

1. Remove PCB by gently

bending the two tabs back
and pull the board up and
out.

2. Remove the sliding

mechanism (you may need
to loosen the friction
adjustment screw).

3. Push out magnet from other

side and swap to desired
position.

ELMDENE INTERNATIONAL LIMITED
3 KEEL CLOSE
INTERCHANGE PARK
PORTSMOUTH
HAMPSHIRE
PO3 5QD, UK

TEL: +44 (0) 23 9269 6638
FAX: +44 (0) 23 9266 0483

www.elmdene.co.uk

Features include:

• Silent two button operation
• Compliant with PD6662: 2010, and the requirements of EN 50131-1:2006, Security

grade 3, Environmental class II.

• Suitable for use under the ACPO “10 point plan” for false PA reduction
• Integral, selectable resistor values for easy FSL connection to most alarm control

panels.

• Alternative double pole wiring option
• Spare terminals for connection of multiple units
• Key operated mechanical reset
• Selectable normally open or normally closed alarm contacts
• Cover and removal from wall tamper (normally closed)
• Visual indication of ready or latched state

Panic alarm trigger device with two push buttons

Meets the requirements of

10 at Grade 3, Environmental Class II

A range of aesthetically pleasing two button panic alarm (PA) devices available with black,
white, brass or stainless steel appearance covers. Suitable for commercial and domestic
installation

PD6662: 20

and EN

50131-1:2006.

.

Отзывы: