Multiple PA (Parallel Resistor Configuration)
FSL Wiring
Two PA (Series Resistor Configuration)
Shunt R
EOL R
LX
ü
û
û
Shunt R
EOL R
LX
û
ü
ü
Single PA (Parallel or Series)
Two PA (Parallel Resistor Configuration)
Follow Instructions
ü
û
=
Fit jumper shown
=
Do Not Fit jumper
LX = Link near terminal 1
For additional PAs, connect as “Other PAs”
Shunt R
EOL R
LX
ü
û
ü
Jumper
Settings
PA 1
PA 2
To
Control
Panel
6
5
4
3
2
1
To
Control
Panel
6
5
4
3
2
1
6
5
4
3
2
1
Jumper
Settings
PA 1
PA 2
Jumper
Settings
Shunt R
EOL R
LX
ü
ü
ü
Multiple PA (Series Resistor Configuration)
To
Control
Panel
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
Shunt R
EOL R
LX
û
ü
ü
Last PA
Shunt R
EOL R
LX
û
û
û
Other PAs
Shunt R
EOL R
LX
ü
û
û
Shunt R
EOL R
LX
û
û
û
Jumper
Settings
First PA
Second PA
6
5
4
3
2
1
To
Control
Panel
6
5
4
3
2
1
6
5
4
3
2
1
For additional PAs, connect as “Other PAs”
Shunt R
EOL R
LX
û
û
û
Last PA
Shunt R
EOL R
LX
û
û
û
Last but one PA
Shunt R
EOL R
LX
ü
û
ü
Shunt R
EOL R
LX
û
û
û
Jumper
Settings
First PA
Shunt R
EOL R
LX
û
û
û
6
5
4
3
2
1
Two PA
PA 1
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
PA 2
Wiring the PA Button
Connections to the PA button are made via the screw terminals numbered 1 to 6.
Configuration of the resistor values to match the alarm panel is by link jumpers.
See the table below to find the resistor values and series or parallel option
needed.
Shunt and EOL Resistors by Control Panel Manufacturer
Control Panel
Shunt
EOL
Configuration
Resistor Resistor
ADE, Bosch, Castle, Menvier, Pyronix, Scantronic, Texecom 4k7
2k2
Series
Honeywell (Galaxy)
1k0
1k0
Series
Guardall
8k2
8k2
Parallel
GE, Aritech, Pyronix
4k7
4k7
Series
Gardtec
6k8
4k7
Series
Bosch, Europlex
2k2
2k2
Series
DSC
5k6
5k6
Series
FSL Wiring (Shunt and EOL Resistor)
Location of Configuration Parts
1
2
3
4
5
6
Terminal
Connections
EOL Resistor
(Chosen by link jumper)
Shunt Resistor
(Chosen by link jumper)
Configuration
LX
(See text and diagrams)
= LX Jumper Not Fitted
= LX Jumper Fitted
Double Pole Wiring -
REMOVE ALL JUMPERS
Double Pole Wiring -
REMOVE ALL JUMPERS
Single PA
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
6
5
4
3
2
1
Multiple PA
First PA
Tamper
Circuit
6
5
4
3
2
1
Alarm
Circuit
6
5
4
3
2
1
6
5
4
3
2
1
Other PAs
Last PA
For additional PAs, connect
as “Other PAs”
Last but one PA
Other PAs
= LX Jumper Not Fitted
= LX Jumper Fitted