background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SwemaFlow 125D 

Dansk manual  

    

 

Side  3 - 8 

English usermanual               

Page  9 - 14 

 

DK: 63 98 950 358 
 
EAN: 5703317570475 

 
 

Содержание SwemaFlow 125D

Страница 1: ...SwemaFlow 125D Dansk manual Side 3 8 English usermanual Page 9 14 DK 63 98 950 358 EAN 5703317570475...

Страница 2: ...mmelse 6 Opladning 8 Batterikontrol 8 Kalibrering 8 Tekniske data 8 English user manual 9 General 9 The measuring equipment includes 9 Accessories 9 Function 9 On Off RED button 9 Unit BLUE button 9 M...

Страница 3: ...ode p 2 sek Gennemsnits flowet vises p displayet med opdatering hvert 2 sek SwemaFlow 125D kompenserer automatisk for luftt theden ved m ling af lufttemperatur og barometrisk tryk T nd sluk r d knap T...

Страница 4: ...ed og uden en dr vle ring kan SwemaFlow125D beregne flowet som afspejler det sande flow uden nogen form for forstyrrelse opfangelse Det er lige meget om man p begynder sin m ling med eller uden dr vle...

Страница 5: ...an holder den sorte knap nede i 2 sek Displayet vil vise hvilket notenummer f eks n 001 Note 1 som m lingen vil blive gemt under for herefter at vende tilbage til normal m lefunktion igen Hvis man nsk...

Страница 6: ...live vist i displayet For at komme ind i Note book skal man trykke p den sorte knap n xxx xxx vil v re nummeret for den sidst gemte note se afsnittet gem m linger vil blive vist i displayet Med den bl...

Страница 7: ...tryk Sort knap Langt tryk Sort knap Langt tryk Sort knap Kort tryk Bl knap R d knap Gr knap Gem m ling Gem m ling Hold funktion Flow faktor m lefunktion ndre FF v rdi Gemt m ling i hukommelsen Alle no...

Страница 8: ...efter N r batterisp ndingen er lavere end 3 2V vil et batterisymbol fremkomme p displayet N r batterisp ndingen er lavere end 2 9V vil instrumentet automatisk slukke Kalibrering SwemaFlow 125D er kali...

Страница 9: ...Function SwemaFlow 125D calculates the average value of the airflow during 2 seconds The average flow is presented on the display with an update two times per second SwemaFlow 125D compensate automati...

Страница 10: ...ssure mode By measuring two times with and without an extra throttle ring SwemaFlow 125D calculates the flow that reflects the true flow with no capture interference It doesn t matter if you start to...

Страница 11: ...in the note book and then returns to measuring mode If you don t want to save the measurement just press the BLACK button and you will return to measurement mode without saving FF Mode Flow Factor It...

Страница 12: ...l be the number of the last saved note see Save measurment will be shown in the display With GREY and BLUE button it s possible to scroll through the saved notes To return to notE press RED button To...

Страница 13: ...When turning on the instrument the display shows the voltage of the battery A fully charged instrument shows approximately 4 1 V it will drop to 3 8 3 9V quite fast When the supply voltage is lower t...

Страница 14: ...ometer 600 1200 hPa 18 35 inHg Accuracy 95 coverage probability in non condensing non moist air 80 RH Air Flow 3 5 read value min 0 4 l s Using Back pressure method 10 min 1 l s Temperature 0 5 C Baro...

Страница 15: ...SwemaFlow 125D side 15 Egne notater...

Страница 16: ...SwemaFlow 125D side 16 TG 22 06 2012 ver 1...

Отзывы: