DC Current (Only Elma 3039) 

Range

 

Resolution

 

Accuracy

 

60.00A * 

0.01A 

±(1.5%+10 digits) ** 

300.0A 

0.1A 

±(1.5%+5 digits) 

* < 0.3A variations as measuring in different directions 
** Add 10 digits to accuracy of 60.00A range in Auto detection function. 
All specs are valid from 5% to 100% of each range. 

AC Current 

Range

 

Resolution

 

Accuracy 
(50…60Hz) 
(Only Elma 
3037) 

Accuracy 
(50…100Hz) 
(Only Elma 
3039) 

Accuracy 
(100…400Hz) 
(Only Elma 
3039) 

60.00A 

0.01A 

±(2.0%+5 
digits) 

±(1.5%+5 
digits) 

±(2.5%+5 
digits) 

300.0A 

0.1A 

LCD displays 0 counts when the reading <20 counts. 
Frequency response:  (Only Elma 3039) 50…400Hz (Sine wave). 
All specifications are valid from 5% to 100% of each range. 

Low pass filter 

Range

 

Resolution

 

Accuracy (50/60Hz) 

60.00A 

0.01A 

±(3.5%+5 digits) 

300.0A 

0.1A 

±(3.5%+5 digits) 

LCD displays 0 counts when the reading <20 counts; Cut-off frequency 
(-3dB): Approx. 160Hz; Attenuation Characteristic: Approx. -24dB/Oct. 
All specs are valid from 5% to 100% of each range. 

Inrush current 

Range 

Resolution 

300.0A 

0.1A 

Integration time: 100ms; Trigger current: 5A 

Voltsense 

Voltage range: 80…600V (At the tip of the clamp)

 

 

Содержание 3037

Страница 1: ...Elma 3037 3039 Clamp Meter Elma 3039 https www elso sk product php id_product 3219 EAN 5706445900046 5706445900053...

Страница 2: ...ttery indicator Do not use Meter around explosive gas or vapor To reduce the risk of fire or electric shock do not expose this product to rain or moisture Individual protective equipment should be use...

Страница 3: ...shut it off Auto power off The instrument shuts off automatically after 20 minutes without buttons pushed Deactivate Auto power off When the instrument is off push and hold down while turning the inst...

Страница 4: ...shown in the display When the current exceeds 5A the instrument calculates the RMS value for 100ms Low pass filter When measuring AC push the button to enable Low pass filter LPF is shown in the displ...

Страница 5: ...rature 20 C 60 C 80 RH no batteries Temperature coefficient 0 2x accuracy C 18 C 28 C Pollution degree 2 Chock vibration MIL PRF 28800F for A class 2 instr Drop protection 1 2m drop to hardwood on con...

Страница 6: ...A 2 0 5 digits 1 5 5 digits 2 5 5 digits 300 0A 0 1A LCD displays 0 counts when the reading 20 counts Frequency response Only Elma 3039 50 400Hz Sine wave All specifications are valid from 5 to 100 of...

Страница 7: ...to repair this instrument The instrument contains no user serviceable parts The instrument should be turned in to Elma Instruments for service Cleaning Periodically wipe the case with a dry cloth and...

Страница 8: ...Elma 3037 3039 20 MD 20131023 v1 4...

Отзывы: