3. Interface Instruction

7

Connect the remote temperature sensor cable (model: RTS300R47K3.81A) Connect one end of the 
remote temperature sensor cable to the interface 

and place the other end close to the battery. 

Step 5: Connect Accessory

3.1 Indicator

Step 6: Recheck if the wire connection is correct

Step 7: Rower on the inverter/ charger

① 

Turn on the circuit breaker at the battery end. 

② 

Switch on the switch then the inverter indicator is on.

③ 

Turn on the breaker of PV array and Utility. 

④ 

Turn on the AC load when the AC output is normal. 

NOTE: 

 

The temperature sensor short-circuited or damaged, the inverter/charger will 

be charging or discharging at the default temperature. 

NOTE: 

 

In case the power is supplied to the different AC loads, it is suggested to turn on the loads with larger 

surge current,  till the load working well, then turn on the loads with smaller surge current. 

NOTE:   In  case the  inverter/charger  is  not  in  normal  operation,  or  LCD  or  indicator displays abnormal, 
refer to Section 5 to clear the fault or contact the after-sale service personnel of our company. 

 

 
 

 

 

 

 

 

NOTE:   The installation steps and accessory list also refer to the cardboard in the package. 

Содержание FBIC5KV4880

Страница 1: ...5000VA Inverter Charger FBIC5KV4880 User Manual Please read this guide carefully before using this product...

Страница 2: ...devices The UPower series is a new type of the inverter charger combining with solar utility charging and AC output which adopts a multi core processor design and advanced MPPT control algorithm and...

Страница 3: ...operating state Provided with common interface and advanced interface Multiple LED indicators that instantly indicate the operating state of the system 2P circuit breaker provided at the utility inpu...

Страница 4: ...Schematic Diagram for Connections Warning Confirm the AC load power compatible with the power of the inverter charger AC load selected exceeding the maximum output power of inverter charger is prohib...

Страница 5: ...t sunshine and rain infiltration High voltage still exists inside the inverter charger after switching off the power switch do not turn on or touch the internal units conduct the associated operation...

Страница 6: ...le solar system components is far NOTE The above wire and the circuit breaker size are for recommended use only please choose the suitable wire and circuit breaker according to the practical situation...

Страница 7: ...hicker wire wire is not less than 4mm2 the grounding point shall be as close as possible to the inverter charger the grounding wire shall be as short as possible AC output Ground and PV wiring termina...

Страница 8: ...ility Turn on the AC load when the AC output is normal NOTE The temperature sensor short circuited or damaged the inverter charger will be charging or discharging at the default temperature NOTE In ca...

Страница 9: ...Output On Solid Load Output Green OFF Relay Turn Off On Solid Relay Turn On Green OFF Input Voltage 3 3 12VDC On Solid No Input Voltage Green OFF Inverter Output On Solid OFF On Solid Utility Output...

Страница 10: ...nnected and Input PV Connected and Input No Utility Connecting Utility Connecting but no input No PV Connecting PV Connecting but No Input Load ON Load OFF Battery capacity level 8 25 Battery capacity...

Страница 11: ...INPUT Solar Priority The battery is charged in solar priority modeand when the battery voltage is lower than Auxiliary Module ON Voltage VAON the utility starts charging When the battery voltage reac...

Страница 12: ...firmaton Step 4 Press the button to exit the setting interface Setting Item LCD Instruction Default Range 1 BTP Battery Type AGM AGM GEL FLD USER 2 CSP Charge Source Priority Solar priority Solar Prio...

Страница 13: ...y module ON voltage 56 0 VDC User 48 0 59 2 VDC Step size 0 4VDC 16 AON 48 0 VDC 17 DON 44 4 VDC User 43 2 48 0VDC Step size 0 4VDC 18 DOF Dry connect OFF voltage Dry connect ON voltage 48 0 VDC User...

Страница 14: ...the Low Voltage Disconnect Voltage LVD the coil of relay is energized and the switch is turned on The dry contact can drive resistive loads 125VAC 1A 30VDC 1A NOTE If it is to change the range of inp...

Страница 15: ...the set point of Low Voltage Disconnect Voltage the controller will stop discharging the battery to protect the battery from being over discharged to break down Load Output Short Circuit Load Output O...

Страница 16: ...onment Make sure no block on air flow around the inverter charger Clear up any dirt and fragments on radiator Check all the naked wires to make sure insulation is not damaged for serious solarization...

Страница 17: ...rent Max PV Open Circuit Voltage 200 VDC 180 VDC Max PV Input Power 4000W Max PV Charging Current 80A Equalization Voltage 58 4 VDC Boost Voltage 57 6 VDC Utility Input Solar Charging Others Mechanica...

Страница 18: ...17 NOTES...

Страница 19: ...18 NOTES...

Страница 20: ...Help Line South Africa 0861 ELLIES 355437 For branch or agent contact details please refer to website www ellies co za...

Отзывы: