3. Interface Instruction
7
Connect the remote temperature sensor cable (model: RTS300R47K3.81A) Connect one end of the
remote temperature sensor cable to the interface
6
and place the other end close to the battery.
Step 5: Connect Accessory
3.1 Indicator
Step 6: Recheck if the wire connection is correct
Step 7: Rower on the inverter/ charger
①
Turn on the circuit breaker at the battery end.
②
Switch on the switch then the inverter indicator is on.
③
Turn on the breaker of PV array and Utility.
④
Turn on the AC load when the AC output is normal.
NOTE:
The temperature sensor short-circuited or damaged, the inverter/charger will
be charging or discharging at the default temperature.
NOTE:
In case the power is supplied to the different AC loads, it is suggested to turn on the loads with larger
surge current, till the load working well, then turn on the loads with smaller surge current.
NOTE: In case the inverter/charger is not in normal operation, or LCD or indicator displays abnormal,
refer to Section 5 to clear the fault or contact the after-sale service personnel of our company.
NOTE: The installation steps and accessory list also refer to the cardboard in the package.