Important Safety Instructions

1. General Information

                           

 

 

 

 

 

 

 

CONTENTS

Important Safety Instructions 

       1

1. 

General 

Information 

        1

2. 

Installation 

Instructions 

       4

3. 

Interface 

Instruction 

        7

4. 

Protection         14

5. 

Troubleshooting 

        14

6. 

Maintenance 

        15

7. 

Technical 

Specifications 

       16

Notes 

         17

• Please  reserve  this  manual  for  future review. This  manual  contains  all instructions about safety, installation and  
  operation for the inverter/charger. 
• Read carefully all the instructions and warnings in the manual before installation. 
• Non-safety voltage exists inside the inverter/charger, users must not dismantle it by itself in order to avoid personal   
   injury, contact professional maintenance personnel of our company in need of maintenance.
• Keep the inverter/charger out the reach of children.
• Do not place the inverter/charger in a damp, oily, inflammable and explosive or a severe environment with a large amount 
  of dust accumulation. 
• The utility input and AC output with high voltage, don’t touch wire connections. Install  the  inverter/charger  in  well 
   ventilated  places,  it’s  shell  may produce heat during operation. 
• It is suggested to install appropriate external fuses/breakers. 
• Make sure switching off all connections with PV array and the fuse/breakers close to battery before inverter/charger  
   installation and adjustment. 
• Make sure all connections remain tight to avoid excessive heat from a loose connection. 
• It’s an off-grid inverter/charger, not for on-grid system. 
• This inverter/charger can only be used singly, parallel or in series connections will damage the devices.

The UPower series is a new type of the inverter/charger combining with solar & utility charging and AC output, which adopts 
a multi-core processor design and advanced MPPT control algorithm, and has the features of high response speed, high 
reliability and high industrialization standard. It offers four charging modes including Solar priority, Utility priority, Solar and 
Utility & Solar; two output modes for Battery and Utility, meeting the various application demands.

The up-to-date optimized MPPT tracking technology is adopted for the PV charging modules. It can quickly track the 
maximum power point of the PV array in any environment and acquire the maximum energy of solar panel in real time;

The advanced control algorithm is adopted for AC-DC charging modules that realize fully digitalized double closed-loop 
control for voltage and current, with high control precision, small volume. The input range of AC voltage is wide, the output 
DC charging voltage/current is continuously adjustable in a certain range, and the complete input/output protection 
functions can offer stable and reliable charging and protection for the battery. 

The DC-AC inverter modules are based on full digital and intelligent design. It adopts the advanced SPWM technology, 
outputs the pure sine wave and converts 24/48VDC to 220/230VAC suitable for AC loads of household appliances, electric 
tools, commercial units, electronic audio and video devices etc. 

The product adopts 4.2 inch LCD display design, which real-time displays the operational data and running state of the 
system. The comprehensive electronic protection function guarantees more safe and more stable operation of the system. 

 

Please reserve this manual for future review. 

1.1 Overview

Содержание FBIC3000VA/24V

Страница 1: ...3000VA Inverter Charger FBIC3000VA 24V FBIC3000VA 48V User Manual Please read this guide carefully before using this product...

Страница 2: ...devices The UPower series is a new type of the inverter charger combining with solar utility charging and AC output which adopts a multi core processor design and advanced MPPT control algorithm and...

Страница 3: ...vanced interface Multiple LED indicators that instantly indicate the operating state of the system 2P circuit breaker provided at the utility input end Independent control of AC output by AC OUT butto...

Страница 4: ...Schematic Diagram for Connections Warning Confirm the AC load power compatible with the power of the inverter charger AC load selected exceeding the maximum output power of inverter charger is prohib...

Страница 5: ...t density in accordance with Article 690 of the National Electrical Code NFPA 70 For outdoor installation keep out of the direct sunshine and rain infiltration High voltage still exists inside the inv...

Страница 6: ...above wire and the circuit breaker size are for recommended use only please choose the suitable wire and circuit breaker according to the practical situation WARNING Risk of explosion Never install th...

Страница 7: ...he thicker wire wire is not less than 4mm2 the grounding point shall be as close as possible to the inverter charger the grounding wire shall be as short as possible AC output Ground and PV wiring ter...

Страница 8: ...d Utility Turn on the AC load when the AC output is normal NOTE The temperature sensor short circuited or damaged the inverter charger will be charging or discharging at the default temperature 250C N...

Страница 9: ...t On Solid Load output Green OFF Relay turn off On Solid Relay turn on Green OFF Inputvoltage 3 3 12VDC On Solid No Inputvoltage Green OFF Inverter output On Solid Utility output Red OFF Device normal...

Страница 10: ...ace 9 Icon instruction Icon instruction Utility connected PV connected No Utility No PV Load ON Load OFF Battery capacity level 8 25 Battery capacity level25 50 Battery capacity level 50 75 Battery ca...

Страница 11: ...Battery Type AGW GEL FLD USER INPUT Solar priority The battery is charged in solar priority modeand when the battery voltage is lower than Auxiliary Module ON Voltage VAON the utility starts charging...

Страница 12: ...on again for confirmaton Step 4 Press the button to exit the setting interface Setting Item LCD Instruction Default Range 1 BTP Battery type AGM AGM GEL FLD USER 2 CSP Charge source priority Solar pri...

Страница 13: ...module ON voltage 28 0VDC User 24 0 29 6VDC Step size 0 2VDC 16 AON 24 0 VDC 17 DON 22 2 VDC User 21 6 24 0VDC Step size 0 2VDC 18 DOF Dry connect OFF voltage Dry connect ON voltage 24 0 VDC User 24 0...

Страница 14: ...is energized and the switch is turned on The dry contact can drive resistive loads 125VAC 1A 30VDC 1A NOTE When the utility input is abnormal this dry contact can control the generator switch to char...

Страница 15: ...the set point of Low Voltage Disconnect Voltage the controller will stop discharging the battery to protect the battery from being over discharged to break down Load Output Short Circuit Load Output O...

Страница 16: ...vironment Make sure no block on air flow around the inverter charger Clear up any dirt and fragments on radiator Check all the naked wires to make sure insulation is not damaged for serious solarizati...

Страница 17: ...me 20mS Max PV Open Circuit Voltage 150V 138V Max PV Input Power 780W 1040W PV Charging Current 30A 20A Equalization Voltage 29 2V 58 4V Boost Voltage 28 8V 57 6V Utility Input Solar Charging Others M...

Страница 18: ...17 NOTES...

Страница 19: ...18 NOTES...

Страница 20: ...Help Line South Africa 0861 ELLIES 355437 For branch or agent contact details please refer to website www ellies co za...

Отзывы: