2.3 Work and operational safety
Warning!

Carefully observe the following notes and the complete 

chapter 2 "Safety”, 

page 6

!

• Before carrying out repairs, cleaning or maintenance work involving the 

power supplies and the discharging bars, switch off the power supply 
and disconnect the mains power supply (see 

chapter 5 "Maintenance”, 

page 13

chapter 6 "Trouble-shooting”, page 14

).

• Before carrying out any work involving the units, the machine which has 

the units fitted must not be in operation (see 

chapter 5 "Maintenance”, 

page 13

chapter 5 "Maintenance”, page 13

).

• Any work involving the units must be carried out by qualified electricians 

(see 

chapter 5 "Maintenance”, page 13

chapter 6 "Trouble-shooting”, 

page 14

).

• Before starting the unit make sure that the appliance is permanently 

grounded via the ground connection (5, Fig. 1). The ground cable 
should have a minimum cross section of 1.5 mm

2

 

(see 

chapter 3.2 

"Ground connection”, page 9

).

• Disconnect and/or connect the bars and the cables only when the 

power supply is swiched off (see 

chapter 3.4 "Connecting the high vol-

W

age cable”, page 10

).

• Terminals at the housing that are not used must be closed with blanking 

plugs (see 

chapter 3.4 "Connecting the high voltage cable”, page 10

).

• Check the units, the electrical wiring and the high voltage cables at 

regular intervals and before the start-up for any damage. Any damaged 
components must be repaired professionally or replaced before con-

tinuing to operate the units.

• If the housing cover is removed, contact protection is no longer effec-

tive. Always disconnect the power before opening the power supply 
units.

• The protection class IP54 only applies if the housing cover is closed 

and the cable connections are shrouded.

• Both the lengths of the high voltage cable and of the active bars are li-

P

ited, observe maximum lengths 

• Please note the maximum total lengths of the bars and the high voltage 

cables in chapter 3.5. (see 

chapter 3.6 "Connecting the supply voltage”, 

page 11

).

• Keep the bars clean at all times. Dirt results in malfunctions and in pre-

mature wear of the units.

• Before starting up the power supply the user must make sure that the 

power supply and the bars have been installed and assembled cor-
rectly. The supply voltage can then be switched on (see 

chapter 4.1 

"Startup”, page 12

).

Содержание ES47 Series

Страница 1: ...Operating Instructions Discharging System BASIX Series ES47 Power Supplies for AC Operation BA en 2075 2111 F01033y...

Страница 2: ...2 BA en 2075 2111_ES47...

Страница 3: ...embly 9 3 1 Assembling the power supply 9 3 2 Ground connection 9 3 3 Selecting the discharging bars 9 3 4 Connecting the high voltage cable 10 3 5 Maximum active bar length and length of the high vol...

Страница 4: ...mpair production processes and need to be eliminated The ES47 power supply features the following characteristics 4 high voltage outputs stable 5 kV AC output voltage small dimensions easy installatio...

Страница 5: ...gh voltage connections 4 pcs 3 1 Shown with high voltage plug connected 3 2 Shown as delivered 4 Supply voltage conductor 5 Ground connection 6 Mounting lug 7 Mounting bolts housing cover X1 Ground co...

Страница 6: ...tions please refer to the General Terms and Conditions GTC see www eltex de 2 1 Proper use The ES47 Power Supplies may be operated only in connection with the Eltex R47 discharging bars the R36 ion bl...

Страница 7: ...3 4 Connecting the high vol Wage cable page 10 Terminals at the housing that are not used must be closed with blanking plugs see chapter 3 4 Connecting the high voltage cable page 10 Check the units...

Страница 8: ...centra tion levels developing near the bars depend on many different factors such as site of installation bar current and voltage air circulation etc and can therefore not be specified in general term...

Страница 9: ...the terminals must be freely accessible at all times 3 2 Ground connection A permanent ground connection must be made via the ground connection 5 Fig 1 The ground cable should have a minimum cross sec...

Страница 10: ...over of the power supply see Fig 1 Remove the nut from the connection at the high voltage cable Insert the connection into the provided opening of the housing Clamp the core of the high voltage cable...

Страница 11: ...ecting the supply voltage Connect the supply voltage via the power supply lead 4 Fig 1 using an earthing pin plug depending on country To ensure that no voltage is supplied to the bars when the materi...

Страница 12: ...ave been installed and assembled correctly The supply voltage can then be switched on Use the toggle switch 1 Fig 1 to switch on the power supply In the ON position the switch lights up green High vol...

Страница 13: ...cation and must hence be defined by the user according to the operating conditions The power supply itself does not require any maintenance Check for correct ground connection Discharging bars To ens...

Страница 14: ...itted must not be in operation Any work involving the units must be carried out by qualified electrici ans Fault Cause Measure No high voltage Lamp in mains power switch lit transformer defective Lamp...

Страница 15: ...rotection class Dimensions Weight UL Approval 230 V AC 50 60 Hz 115 V AC 60 Hz max 25 VA 5 kV AC depending on length of bar and length of high voltage cable see 3 5 max 2 4 mA at 5 kV 0 50 C 32 122 F...

Страница 16: ...16 BA en 2075 2111_ES47 8 Dimensions Fig 5 Dimensions ES47 Power Supply Z 113409by...

Страница 17: ...specify cable length Plug X Kit for cutting high voltage cable to size without flexible tube for bar R47 Hexagonal crimper 5 41 mm Blanking plug M16 x 1 5 Nut M16 x 1 5 Mains cable gland Fuse F1 115 V...

Страница 18: ...18 BA en 2075 2111_ES47...

Страница 19: ......

Страница 20: ...stra e 67 69 79576 Weil am Rhein Germany Telefon 49 0 7621 7905 422 eMail info eltex de Internet www eltex de Eltex Unternehmen und Vertretungen Die aktuellen Adressen aller Eltex Vertretungen finden...

Отзывы: