14
BA-en-2075-2111_ES47
6. Trouble-shooting
Warning!
Electric shock hazard!
• Switch the power supply off and disconnect the supply voltage before
carrying out any maintenance or repair work.
• The machine which has the units fitted must not be in operation.
• Any work involving the units must be carried out by qualified electrici-
ans..
Fault
Cause
Measure
No high voltage
• Lamp in mains power
switch lit: transformer
defective.
• Lamp in mains power
switch fails to light:
supply voltage not
enabled or not con-
nected.
• Defective fuse.
Inform Eltex Service.
Check supply voltage
and connections. Check
connected cables, cable
connections and bars.
Replace fuse.