13/40
STEP 3 - Functional check and first Web Server access
1.
Before accessing the Web server board,
set
in the Technical menu of the Control panel, in the
item MAINTENANCE
OPERATION MODE, the
MODE-2
or
MODE-0
; and in the item
PROGRAMMING
SECTORS
CONFIGURE SECTORS, remove the BLOCK ACTIVATION
function for all the configured sectors.
2.
Perform an operational check on the LAN network using your PC browser, by typing in the
address bar the IP address assigned during the initialisation of the Web Server board.
(e.g. >> 192.168.xxx.xxx)
3.
Once connection is established, a dialogue box will be displayed where you will be prompted to
enter your "User Name and Password" for first access to the Web Server.
Use the factory credentials User =
admin
and Password =
WebServer1
.
The Web Server is compatible with the following browsers:
Google Chrome
, from version 36.0.1985.125 m
Firefox
, from version 30
Microsoft IE
, from version 9
Safari
, from version 5.1.7
WARNING!
After 2 minutes of open page inactivity or waiting time, the page will be timed
out and automatically quitted.
4.
Immediately after logging in, the system requires that User Name and Password credentials be
changed. These credentials should be set according to the security criteria recommended in the
registration page:
Minimum 8 characters
At least one uppercase character
At least one lowercase character
At least one digit
WARNING!
Simultaneous accesses are not allowed.
5.
Access the Homepage with your new credentials by selecting the desired section among those
listed.
6.
Log in order to access the menus, by using the
MASTER code
of the alarm control panel MPxx
(the same code typed on the keypads - the default code being: 111111).