20
MP500/4-8-16
1.5.2
How to view open inputs with operating mode “0”
The presence of one or more open inputs is indicated by the specific LED on the keypad and by the reader LED.
These LEDs also indicate the opening of isolated inputs.
To view input addresses you can proceed in two ways:
Without entering a valid code
: in this case the open inputs viewed are those which have at least one partition in common with the
keypad being operated.
1) Press the
MENU
key and then press
repeatedly until OPEN INPUTS appears.
2) Press
. The inputs are identified as “<Logical address>:<Name>” on the second line. For
example, an input to which the kitchen detector is connected with logical address “3” and named
“Kitchen” will be identified as “In003:Kitchen”.
3) Use
and
to scroll the list of open inputs.
4) Press
and
to see the input customisation.
5) Press
repeatedly to exit from the menu after examining the list.
Entering a valid code
: in this case the open inputs viewed are those which have at least one partition in common with the keypad being
operated and the valid code entered.
1) Enter
<Master / User / Installer / Technical Manager code>
, press
twice and then press
repeatedly until OPEN INPUTS appears.
2) Press
. The inputs are identified as “<Logical address>:<Name>” on the second line. For
example, an input to which the kitchen detector is connected with logical address “3” and named
“Kitchen” will be identified as “In003:Kitchen”.
3) Use
and
to scroll the list of open inputs.
4) Press
and
to see the input customisation.
5) Press
repeatedly to exit from the menu after examining the list.
SYSTEM STATUS
OPEN INPUTS
OPEN INPUTS
In001:...
MP500/16
12/01/2014 10:10
UT02:...
OPEN INPUTS
OPEN INPUTS
In001:...
MP500/16
12/01/2014 10:10
Содержание ELKUMP500/16