3/20
SLEEP TIMER
•
The EIR features an automatic “
sleep time
” of approximately one minute for power conservation.
After transmitting a detected movement, the EIR will not retransmit for one minute. Any further
movement detected within this one-minute sleep period will extend the sleep time by another
minute. This way, continuous movement in front of a EIR will not unduly exhaust the battery.
DIP SWITCH POSITION TABLE
•
The function of each DIP Switch is listed as the table below. The DIP Switch is either ON or OFF.
Top position indicates ON and bottom position indicates OFF.
DIP
Position
Function
DIP
Sensitivity Level
ON Test
Mode
Switch 5
Switch 6
Switch 1
OFF
Normal Mode (default)
ON
ON
Low; for 75 cm / 60 kg pet
ON
Supervision Disable
ON
OFF
Medium; for 60 cm / 40 kg pet
Switch 2
OFF
Supervision Enable
OFF
ON
High; for 45 cm / 30 kg pet
ON
EIR facing a wall within 10 m
OFF
OFF
Superior; for 30 cm / 20 kg pet (default)
Switch 3
OFF
EIR facing an open space
(no wall within 10 m)(default)
DIP
Position
Function
ON
EIR facing a lawn (default)
ON
Switch 4
OFF
EIR facing a concrete/stone ground
Switch 7
OFF
Reserved
ON
Switch 8
OFF
Reserved
GETTING STARTED – LEARNING THE EIR INTO THE CONTROL PANEL
•
Loosen the fixing screws and remove the cover assembly.
•
Based on your needs, set Sensitivity Switch as shown in DIP Switch Position Table.
•
Insert two 3.6V AA lithium batteries into the battery holder taking care to connect the polarity
correctly.
•
The LED indicator will flash for 30 seconds. The EIR is warming up. During the warming period,
the EIR is not activated. It is recommended that you stay away from the detection area during this
time. After the warming period is over, the LED dims and the EIR is ready to operate.
•
Navigate the Control Panel into “
/-
” menu and then select “
Add Device
” menu.
•
Press the Test button on the front cover.
•
Refer to the operation manual of your Control Panel under the section “
/-
” to complete
the learn-in process (for certain Control Panel models, the EIR can be learnt in as a regular PIR
with programmable attributes and thus the Control Panel will report when an alarm is triggered).
•
After the EIR is learnt-in, navigate the Control Panel into “
Walk Test
”. Hold the EIR in the desired
location, and press the Test button to confirm this location is within the signal range of the Control
Panel.
•
When you are satisfied that the EIR work in the chosen location, you can proceed to installation.
Note:
Walk Test should be conducted to confirm proper operation and coverage of the EIR.
ON
OFF