The DC600 and DC600/BR
mini magnetic contact monitors the opening/closing of specific devices (e.g. door or a window). The
contact is fixed onto the door or window frame, while the actuation magnet must be fixed onto the door or window itself. When
the door or window is opened, the magnet moves away from the contact making the inner magnetic switch trip and activating
the sending of an alarm signal to the control panel. The device can also send information on faults and flat battery indications.
The contact consists of a cover and a base. The cover contains all the electronic components, while the base is used for
installing the device. A tamper switch inside provides protection from unauthorised attempts to open or remove the device.
P
P
a
a
r
r
t
t
i
i
d
d
e
e
n
n
t
t
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
1. LED indicator
2. Learning/test button
-
Press the test button to transmit data for learning
by the control unit
.
-
Press once to enter Test mode for three minutes
.
3. Battery
4. Cover Fastening screw hole
5. Provision for holes
6. Tamper switch
7. Battery insulation hole
8. Magnet position indicators
9. Magnet
Position the magnet on the side of the contact
between the two indicators. The contact may be installed either straight or upside down to
ensure that the indicators are aligned with the magnet.
10. Magnet fixing screw hole
11. Magnet spacer
A
A
c
c
c
c
e
e
s
s
s
s
o
o
r
r
i
i
e
e
s
s
i
i
n
n
c
c
l
l
u
u
d
d
e
e
d
d
1 magnet
2 screws
2 anchor bolts
1 two-sided adhesive for magnet
2 screws for magnet
2 spacers for magnet
L
L
E
E
D
D
In normal operating mode, the LED is off, except for the following situations:
When the tamper switch of the contact is opened
When the battery of the contact is flat
When the contact is in Test mode
The LED does not blink if the tamper switch and the battery contact are working normally and not in Test mode.
The LED blinks to indicate that a signal is being transmitted and blinks rapidly twice when it receives a recognition signal
from the control unit.
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
i
i
o
o
n
n
In normal operation conditions, the contact transmits a supervision signal at intervals from 30 to 50 minutes to the
control unit.
If the supervision test was activated on the control panel and the control panel does not receive the signal from the
contact within a predetermined time, the control unit will generate a supervision alarm.
T
T
a
a
m
m
p
p
e
e
r
r
s
s
w
w
i
i
t
t
c
c
h
h
This protects from attempts to removal or opening of the casing. When the tamper switch is open, the contact sends
an alarm signal to the control unit and the LED is lit.
B
B
a
a
t
t
t
t
e
e
r
r
y
y
The contact is powered by a
CR2 3 V lithium battery
and can indicate when the battery is flat. When the battery is flat,
the device sends a signal to the control unit together with normal transmission. The LED lights up when the contact alarm
is tripped with battery flat. When the battery is completely flat, the contact does not indicate alarms and the LED blinks
every 4 seconds.
How to change the battery:
After the battery has been removed, press the learning/test button 5-6 times to completely discharge the device
before inserting the new battery.
<
<
N
N
O
O
T
T
E
E
>
>
After inserting a new battery, the contact will check whether the battery is working correctly or not within 16 minutes
from its insertion.