(((ELKRON))) - CT10-M / CT11-M
37
8.14 OUTPUT PROGRAMMING MENU
• This function is used to program with status of outputs U3, U4, U5.
• Each output can be CONTROLLED remotely or ASSOCIATED TO AN INPUT (see page 9,
“Description of outputs”).
to confirm
the selection
to select the outputs
to confirm
the selection
to confirm
the selection
ENGINEER MENU
OUTPUTS PROG.
OUTPUTS PROG.
OUTPUT NR : 3 OUTPUTS PROG.
OUTPUT NR : 4 OUTPUTS PROG.
OUTPUT NR: 5
OUTPUTN : 3
SWITCHABLE
OUTPUT : 3
STEADY
OUTPUT N : 3
NOT USED
OUTPUT N : 3
LINK INP.1
OUTPUT N : 3
LINK INP.2
OUTPUT : 3
5 SEC TIMED
OUTPUT : 3
90 S TIMED