Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. 

Installation and connection can be carried out only by a person with adequate professional qualification upon 

understanding this instruction manual and functions of the device, and while observing all valid regulations. 

Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any 

sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It 

is necessary to treat this product and its parts as electronic waste after its lifetime is terminated.  Before starting 

installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing 

observe safety regulations, norms, directives and professional, and export regulations for working with electrical 

devices. Do not touch parts of the device that are energized – life threat.  Due to transmissivity of RF signal, observe 

correct location of RF components in a building where the installation is taking place. RF Control is designated only 

for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not 

be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is 

then impossible.  RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an 

obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control. 

Warning

Accessories /

Flood sensor FP-1 

 

the flood sensor is designed to detect flooding, especially in residential areas, over flowing 

bathes, disorders of washing machines, dishwashers, boilers, etc.

SHR-1-M: brass sensor

SHR-1-N: stainless steel sensor

 

sensor to control flooding

Level probe SHR-2

 

detection sensor is electrode, which in connection with switchable device is used for level 

detection for example in wells,tanks...

Measuring probe /

Technical parameters /

Supply voltage:
Battery life:
Indication of transmission/function:
Reset after flooding:
Programming:
Measuring input:
Voltage at measuring input:
Resistance at measuring input for 
flood detection:
Resistance at measuring input for 
run-off detection:
Probe wire length:
Frequency:
Signal transmission method:

Range in the open:
Other data
Working temperature:
Working position:
Fixing:
Degree of protection:
Pollution degree:
Dimensions:
Weight:
Relating standards:

Attention:

When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.

Between the individual commands must be an interval of at least 1s.

Prekidač nivoa (Level switch)

RS

 www.elkoep.rs

U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected] 

U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected] 

 

EN

 Support: +381 63 479 880 | 

RS

Tehnička podrška +381 63 479 880 

Dodatni pribor 

Merne sonde

Sonda za poplavu FP-1

 

• sonda za poplavu je dizajnirana za otkrivanje poplava, posebno u dnevnim boravcima, 

prelivenim kupkama, kvarovima na mašini za pranje veša, mašini za pranje sudova, kotlu itd.

 

 

Sonda za nivo SHR-1-M - mesingana sonda

 

Sonda za nivo SHR-1-N - sonda od nerđajućeg čelika

 

• sonde dizajnirane za nadgledanje poplava

 

 

Sonda nivoa SHR-2

 

• sonda za otkrivanje je elektroda koja se, zajedno sa odgovarajućim uređajem za procenu, 

koristi za otkrivanje nivoa, npr. U bunarima, bušotinama, rezervoarima ...

Tehnički paramteri

Napon napajanja:
Trajanje baterije:
Indikacija prenosa/funkcija:
RESET – nakon poplave
Programiranje:
Merni ulaz:
Ulaz za merenje napona:
Ulaz merenja otpora za detekciju 
poplava:
Ulaz merenja otpora za  detekci-
ju ispiranja: 
Dužina kabla za sondu:
Frekvencija:
Metoda prenosa signala:

Domet na otvorenom prostoru:
Ostali podaci
Radna temperatura:
Pozicija rada:
Montaža: 
Stepen zaštite:
Stepen zagađenja:
Dimenzije:
Težina:
Standardi:

1 x 3V batteries / baterije CR 2477                  

   1 year / godina    
 red / crvena LED

JUMPER - manual/automatic / Ručno/Automatsko

with Prog button/based batteries / sa programskim tasterom/baterijama

terminal / terminal  0.5-1mm

2

3V

≤ 20 kΩ

≥ 40 kΩ

max. 30 m

866 MHz, 868 MHz, 916 MHz 

bi-directional addressed message /

dvosmerna adresirana poruka

up to / do 160 m

-10...+50 °C

any / bilo gde

glue, screws / lepak, zavtanj

IP30

2

 49 x 49 x 13 mm

45 g                                         

EN 60730-1, EN 300 220, EN 301 489 directive R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/

EC)

Uputstva za upotrebu su namenjena za ugradnju kao i za korisnike proizvoda. Uputstva se uvek dobijaju uz 

proizvod. Instalaciju i povezivanje smeju da obavljaju samo kvalifikovane osobe, u skladu sa svim važećim 

propisima, koja je detaljno upoznata sa ovim uputstvom i funkcijama komponenti. Funkcija elemenata takođe 

zavisi od prethodnog načina transporta, skladištenja i rukovanja. Ako u bilo kom slučaju primetite nekakve 

znakove oštećenja, deformacije, kvara ili ako neki deo nedostaje, nemojte ugrađivati uređaj, prijavite to pro-

davcu. Nakon što kopmonenti istekle životni vek, potrebno je tretirati je kao elektronski otpad. Pre započinja-

nja instalacije potrebno je prvo se uveriti da su žice, povezani delovi ili terminali bez napona. Tokom instalacije 

i održavanja  moraju se poštovati sigurnosni propisi, standardi, direktive i profesionalne odredbe za rad sa 

električnom opremom. Ne dodirujte elemente pod naponom golim rukama, zbog mogućnosti stujnog udara i 

rizika od smrti.  Zbog propustljivosti RF signala, obratiti pažnju na pravilno postavljanje RF elemenata u zgradi 

gde će se izvoditi ugradnja. RF kontrola je namenjena samo za unutrašnju ugradnju. Elementi nisu namenjeni 

za spoljašnju ugradnju kao i za ugradnju u vlažne prostorije, ne smeju se ugraditi u metalne ormane kao ni 

u plastične ormane sa metalnim vratima iz razloga što će to sprečiti prenos radio frekvencijskog signala. RF 

konrola se ne prepuručuje za kontrolu uređaja koji pružaju životne funkcije kao i za kontrolu opasne opreme 

kao što su  pumpe, električni grejači bez termostata, liftova, dizalica itd. iz razloga što prenos radio frekvencije 

može biti preklopnjen, ometen, baterija predajnika se može isprazniti i na taj način daljinski upravljač može 

biti onemogućen.

Upozorenje

Upozorenje:

Kada instalirate iNELS RF Control sistem,  mora se poštovati minimalno rastojanje od 1cm između 

pojedinih elemenata.

Između pojedinačnih komandi potrebno je da prođe interval od 1s.