Technical parameters /
Supply voltage:
Apparent input:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. DC switching power:
Mechanical service life:
Electrical service life (AC1):
Control
RF, by command from transmitter:
Manual control:
Range in free space:
Output for RF antenna:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Connecting conductor cross-section
(mm
2
):
Dimensions:
Weight:
Related standards:
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.
* Max Tightening Torque for antenna connector is 0.56 Nm.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s (Valid for control RE6).
8 / 8
U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected]
U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected]
EN
Support: +381 63 479 880 |
RS
Tehnička podrška +381 63 479 880
www.elkoep.rs
Šestokanalna prekidačka jedinica za kontrolu ventilatora
RS
110-230 V AC / 50-60 Hz
min. 2 VA / max. 5 VA
min. 0.5 W / max. 2.5 W
+10% / -25 %
3x switching / prelaz (AgSnO
2
);
3x switching / promena (AgSnO
2
)
8 A / AC1
2000 VA / AC1
10 A / <3 s
250 V AC1
500 mW
1x10
7
1x10
5
866 MHz, 868 MHz, 916 MHz
button / taster MAN
up to / do 200 m
SMA connector / konektor *
-15 °C ... + 50 °C
any / bilo gde
DIN rail / DIN šina EN 60715
IP20 from the front panel / sa prednje strane panela
III.
2
max. 1x2.5, max. 2x1.5 / with a hollow /
sa šupljinom maks.1x2.5
90 x 52 x 65 mm
264 g
EN 60669, EN 300 220, EN 301 489 R&TTE Directive,
Order. No 426/2000 Coll. (Directive 1999/EC
Tehnički parametri
Napon napajanja:
Prividna snaga ulaza:
Maksimalna potrošnja:
Tolerancija napajanja:
Izlazi
Broj kontakata:
Nominalna struja:
Prekidačka snaga:
Maksimalna snaga:
Prekidački napon:
Min. DC preklopna snaga:
Mehanički radni vek:
Električni radni vek (AC1):
Kontrola
Frekvencija:
Ručna kontrola:
Domet na otvorenom prostoru:
RF antena
Ostali podaci
Radna temperatura:
Pozicija rada:
Montaža:
Stepen zaštite:
Kategorija prenapona:
Stepen zagađenja:
Presek provodnika za povezivanje
(mm2):
Dimenzije:
Težina:
Standardi :
Upozorenje
Uputstva za upotrebu su namenjena za ugradnju kao i za korisnike proizvoda. Uputstva se uvek dobijaju uz
proizvod. Instalaciju i povezivanje smeju da obavljaju samo kvalifikovane osobe, u skladu sa svim važećim
propisima, koja je detaljno upoznata sa ovim uputstvom i funkcijama komponenti. Funkcija elemenata takođe
zavisi od prethodnog načina transporta, skladištenja i rukovanja. Ako u bilo kom slučaju primetite nekakve
znakove oštećenja, deformacije, kvara ili ako neki deo nedostaje, nemojte ugrađivati uređaj, prijavite to pro-
davcu. Nakon što kopmonenti istekle životni vek, potrebno je tretirati je kao elektronski otpad. Pre započinja-
nja instalacije potrebno je prvo se uveriti da su žice, povezani delovi ili terminali bez napona. Tokom instalacije
i održavanja moraju se poštovati sigurnosni propisi, standardi, direktive i profesionalne odredbe za rad sa
električnom opremom. Ne dodirujte elemente pod naponom golim rukama, zbog mogućnosti stujnog udara i
rizika od smrti. Zbog propustljivosti RF signala, obratiti pažnju na pravilno postavljanje RF elemenata u zgradi
gde će se izvoditi ugradnja. RF kontrola je namenjena samo za unutrašnju ugradnju. Elementi nisu namenjeni
za spoljašnju ugradnju kao i za ugradnju u vlažne prostorije, ne smeju se ugraditi u metalne ormane kao ni
u plastične ormane sa metalnim vratima iz razloga što će to sprečiti prenos radio frekvencijskog signala. RF
konrola se ne prepuručuje za kontrolu uređaja koji pružaju životne funkcije kao i za kontrolu opasne opreme
kao što su pumpe, električni grejači bez termostata, liftova, dizalica itd. iz razloga što prenos radio frekvencije
može biti preklopnjen, ometen, baterija predajnika se može isprazniti i na taj način daljinski upravljač može
biti onemogućen.
*Maksimalan momenat pritezanja konektora antene je 0.56
Nm.
Upozorenje:
Kada instalirate iNELS RF Control sistem, mora se poštovati minimalno rastojanje od 1cm između
pojedinih elemenata.
Između pojedinačnih komandi potrebno je da prođe interval od 1s.(važi i za RE6).