02-12/2018 Rev.0
RFSA-166M
Wireless switch unit
EN
Made in Czech Republic
1 x
Function delayed on /
Description of delayed on /
The output contact will be opened by pressing the button and closed after the set
time interval has elapsed.
Programming /
Press of programming button
PRG6 on receiver RFSA-166M
for 1 second will activate re-
ceiver RFSA-166M into pro-
gramming mode. LED is flash-
ing in 1s interval.
Assignment of the delayed on
function is performed by six
presses of the selected button
on the RF transmitter (must be
a lapse of 1s between individ-
ual presses).
Press of programming button
PRG6 longer then 5 seconds,
will activate actuator into
timing mode. LED flashs 2x in
each 1s interval. Upon releas-
ing the button, the delayed
return time starts counting.
After the desired time has
elapsed (range of 2s...60min),
the timing mode ends by
pressing the button on the
RF transmitter, to which the
delayed return function is
assigned. This stores the set
time interval into the actuator
memory.
Press of programming button
PRG6 on receiver RFSA-166M
shorter then 1 second will fin-
ish programming mode. The
LED lights up according to the
pre-set memory function.
Programming with RF control units /
address 2 /
The address 2 listed on the front side of the actuator is used for programming and controlling an RF actuator by control
units.
2
6 x
1
PRG6
>
1s
1 x
3
PRG6
>
5s
1 x
4
1 x
t = 2s . . . 60min.
5
PRG6
<
1s
1 x
RFSA-166M
ANT.
Un
HEAT
COOL
1: 0120D1 2: 0120D2
PRG
PRG 6
1
2
3
FAN
SPED
RE1
RE2
RE3
RE4
RE5
RE6
MAN
6 / 8
U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected]
U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected]
EN
Support: +381 63 479 880 |
RS
Tehnička podrška +381 63 479 880
www.elkoep.rs
Šestokanalna prekidačka jedinica za kontrolu ventilatora
RS
Funkcija odloženog uključivanja
Opis funkcije odloženog uključivanja
Izlazni kontakt se otvara / zatvara nakon pritiska na dugme nakon isteka pode-
šenog vremenskog intervala.
Programiranje
Pritiskom na taster za pro-
gramiranje u trajanju od 1
sekunde na RF elementu RF-
SA-166M element se preba-
cuje u režim programiranja.
LED lampica trepće u inter-
valu od 1s.
Potrebno dodeljivanje funk-
cije odloženog uključivanja
vrši se pomoću 6 pritiska iza-
branog tastera na RF kontro-
leru (između pojedinačnih
pritiska mora biti razmak od
1 s).
Pritiskom na taster za pro-
gramiranje duže od 5 sekun-
di element se prebacuje u
režim tajmera. LED trepće
dva puta u intervalima od
1s. Kada se taster otpusti,
vreme funkcije odloženog
uključivanja počinje da se
odbrojava.
Nakon isteka potrebnog
vremena (između 2 s ... 60
min), režim vremena se
prekida pritiskom na taster
na RF kontroleru kojem je
dodeljena funkcija odlože-
nog uključivanja. Ovo štedi
zadati vremenski interval u
memoriji elementa.
Pritiskom na taster za pro-
gramiranje PRG6 na RFSA-
-166M kraćim od 1 sekunde
završava se režim progra-
miranja. LED svetli u skladu
sa podešenom funkcijom
memorije.
Programiranje sa elementima RF sistema
adresa 2
Adresa 2, koja se nalazi na prednjoj strani elementa, koristi se za programiranje i kontrolu elementa pomoću RF
sistema.