Button

 Rooms

 displays created rooms.  

By pressing the button 

(+)

.  

If you click on the button 

(+)

, a table is displayed in which you fill in: 

 

1. 

Label

 gives an arbitrary name to the room (you can use diacritical marks, gaps and others...) 

2. 

Type

 

– here you select the type of room or type of icon that you will then display after entering 

the floorplan on the desktop. 

3. 

Floorplan

 

– here select the floorplan (image) that you added before in the tab 

Floorplans

 

By pressing 

 you can remove all added rooms.  

 

 

 

 

Name of room

Содержание eLAN-RF-003

Страница 1: ...29 10 2020 Page 1 of 18 eLAN RF 003 02 95 2016 rev 10 ...

Страница 2: ...uction 4 2 Installing the eLAN RF 003 IP address 5 3 Logging in to the web interface eLAN RF 003 6 4 Settings 7 Description of functions 8 Adding RF actuators to the floorplan 16 RF control actuators 17 Starting up scenes 17 Error messages on the web interface 18 ...

Страница 3: ...also depends on the way it was shipped stored and handled If you notice any signs of damage deformation malfunction or a missing part do not install this product and return it to the point of sale At the end of its service life the product and its parts must be treated as electronic waste Before starting the installation make sure that all wires and connected parts are not under voltage When assem...

Страница 4: ...hen leaving room video camera integration scenes make multiple commands at once with a single press If you don t have a fixed IP address the Smart RF box will obtain it from DHCP server automatically Power is supplied to the Smart RF box via adapter 10 27V DC included in the supply or PoE by power source router 24V DC By connecting two Smart RF boxes by LAN cable you avoid the problem of lack of s...

Страница 5: ...e for mobile telephone with OS Android download the current version at Google Play under the name iHC MAIRF https play google com store apps details id cz elkoep ihc_marf_us hl en for mobile telephones with IOS download the current version under the name iHC MIIRF in the app store https itunes apple com cz app inels home control rf for iphone id1189384684 mt 8 In the installed application in the S...

Страница 6: ... either as administrator admin with full access to controls and settings user user has the option of controlling the device Both users log into the same dialog field Login Password but each uses his her own name and password Confirm the log in by pressing Login Note Perform RESET of the eLAN RF 003 unit by a long press of the button on the device front panel until the yellow LED starts flashing Re...

Страница 7: ... 4 Settings After logging in your browser opens a window where you can see the devices associated to the room If you set multiple rooms you can switch between them by arrows located in the upper right corner Clicking on the Settings icon displays the menu ...

Страница 8: ...enu settings are displayed By pressing Log out you will log out of the web interface eLAN RF 003 By pressing the button Accounts you will display a window for changing login data By pressing the button Load settings you can restore your stored settings which you have already stored in your PC the file has the extension bin ...

Страница 9: ...ur eLAN RF 003 When updating the eLAN RF 003 proceed according to the following instructions 1 Download the latest firmware version from the website http www elkoep com products inels rf control wireless control system units smart rf box elan rf 003 8488 2 Click on the button Update firmware select the downloaded file the update file must always include the extension bin and click on it After conf...

Страница 10: ...P 20 This means if it receives a command from the RF controller or RF detector it resends it to a designated RF element and vice versa Oasis compatible Enables the repeater function to serve unidirectionally communicating units RF Key RFWB RFIM detectors etc RF Touch compatible Enables the repeater function to serve bidirectionally communicating units RF Touch etc List of addresses Repeated addres...

Страница 11: ...er this receives commands via the Ethernet network and via the RF network Example eLAN Slave catches the RF signal of the RF controller saves it as Repeater signal repeater and sends the RF signal further along Active function Router eLAN is in its basic setting eLAN only receives commands from the Ethernet network and ignores all RF signals Oasis compatible the sames as with the Repeater function...

Страница 12: ...n also set the time zone in which the eLAN is located By selecting Daylight Saving Time you can manually set the daylight saving time Time of eLAN RF 003 is automatically set from NTP server If your eLAN RF 003 is not connected to internet network then time is always set to 12 00 AM the current day is set manually with button Manual During power failure time information is erased from eLAN memory ...

Страница 13: ...ew RF element 1 Product Type select RF element 2 Address enter the address of the RF element that is listed right on the box of the added RF element six character code 3 Label any naming of the element e g Kitchen light 4 Type select the type of icon e g light which will be displayed on the floorplan Create you will store the RF actuator in the eLAN RF 003 Button remove all elements ...

Страница 14: ...you fill in 1 Label gives an arbitrary name to the room you can use diacritical marks gaps and others 2 Type here you select the type of room or type of icon that you will then display after entering the floorplan on the desktop 3 Floorplan here select the floorplan image that you added before in the tab Floorplans By pressing you can remove all added rooms Name of room ...

Страница 15: ...the scene you can use diacritical marks and spaces in between 2 Actions add an RF element When adding an actuator its function action is set switching dimming etc If for an actuator you select the function ON you must still confirm this function by its precise status in the table Choose value e g true for switching on or false switching off After adding all actuators and their required functions c...

Страница 16: ...n Click on Rooms in the room panel where you want to add the required RF components On the desktop menu the room appears there any correction can be made Click the Continue button to display a list components associated with the eLAN Click on individual elements to add to the room If a floor plan is assigned to a room you can move the components in the room freely If a floor plan is not assigned t...

Страница 17: ...ts functions where you can select which function is performed delayed closing including setup time brightness adjustment Thermal components can only be controlled by the application on your phone on the web interface only the information about the measured set temperature is displayed Starting up scenes Clicking on the icon Scenes 3 displays a list of pre set scenes Click on the scene you want to ...

Страница 18: ...016 rev 10 Error messages on the web interface 404 Unavailability of eLAN over the network disconnected from power supply disconnected from Ethernet other error 401 Authorization error key expiration or not initialized in time measured in seconds ...