B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

1

2

3

4

5

6

7

8

9

10A

10B

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

56073C

98501C

98871C

98530C

38417001

75632C

70817C

70020C

28395C

97446C

98481C

111008343890

70432C

28708C

28473C

45767C

28343C

45781C

1000002162

55996C

28383C

28384C

1000003513

1000003514

27026C

45768C

56092C

1000001994

56163C

45769C

75560C

Bubbler Assy

Bubbler Assy (Stream Saver)

Kit - Push Button/Spring/Washer

Kit - Regulator/Holder/Nut

Screw - #8-18 x .37 HHSM

Setscrew - #10-32 x .38

Fttng - Elbow 1/4 x 1/4

Nut - Hex 5/16-18

Bracket - Support

Bubbler Assembly VR

Bubbler Assy. VR StreamSaver

Screw - #10-24 x .62 HHSM

Screw - #8-32 x .38 THSM

Basin - Swirlflow

Lower Shell

Fountain Body

Cover Plate

Sleeve

Kit - Union 1/4” x 1/4” (3 Pack)

Strainer (Provided with Chiller)

Back Panel RH ADA

Back Panel LH ADA

Back Panel RH ADA (Green Spec)

Back Panel LH ADA (Green Spec)

Lower Panel

Drain - Plug 1-1/2”

Poly Tubing (Cut To Length)

Kit - Tee - 1/4” (3 Pack)

Gasket - Drain

Assy - Drain/Tailpipe

Screw - 5/16-18 x 1.00 HHMS

PARTS LIST

ITEM NO. PART NO.

DESCRIPTION

Installation Package

The components for installation are packed in three 

separate boxes, regardless of the type of unit being 

installed. The boxes contain the following:

Box  No. 1: Wall Frame(s)

Box  No. 2: Remote Chiller, ECH8

Box  No. 3: Fountain Arm and Panels

Additional materials, as noted in the Parts List, are also 

shipped in these boxes.

TROUBLESHOOTING & MAINTENANCE

Orifice Assembly:

 Mineral deposits on 

orifice can cause water flow to spurt or not 

regulate. Mineral deposits may be removed 

from the orifice by poking with a small round 

file not over 1/8” diameter, or using a small 

diameter wire

.

 

DO NOT file or cut orifice 

 material.

Stream Regulator: 

If orifice is clean, 

regulate flow as in Step 11 of the installation 

instructions. If replacement is necessary, see 

parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings: 

 

Cooler is provided with lead-free connectors

 

which utilize an o-ring water seal. To remove

 

tubing from the fitting, relieve water 

 

pressure, push in on the gray collar while 

 

pulling on the tubing. (See Figure 13) To 

 

insert tubing, push tube straight into fitting 

 

until it reaches a positive stop approximately 

 3/4”)

.

Figure 13 – Quick Connect Fittings

Figure 12 – Water Supply Connections

ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816

REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640

Содержание SWIRLFLO ERPB2-8C

Страница 1: ...It is common practice to ground electrical hardware such as telephones computers and other devices to available water lines This can however cause electrical feedback in the plumbing circuit which res...

Страница 2: ...B2 8C 3C ERPB2 8GRNC A ERPB2 8GRNRAC A LRPB2 8GRNC A LRPB2 8GRNRAC A Page 2 97924C Rev J 07 16 LEGEND A 1 4 O D Tube Water Outlet Connection B 3 8 O D Tube Water Inlet Connection C 1 1 4 Waste Tube D...

Страница 3: ...ushing it until it reaches a positive stop approximately 3 4 19mm on the marked chiller inlet port Connect building supply line to strainer See Figure 3 Caution DO NOT SOLDER tubes inserted into the s...

Страница 4: ...the chiller 1 4 O D copper tube Install a 1 4 x 1 4 tee provided on the marked chiller outlet port Insert the 1 4 poly tubing coming from the fountain into the union CAUTION DO NOT SOLDER tubes insert...

Страница 5: ...BUBBLER DETAIL NOTE When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten Basin Figure 8 Bubbler Details 1 or 2 Locknut 10A or 10B Bas...

Страница 6: ...PB2 8RAC ERPB2 8C 2C ERPB2 8C 3C ERPB2 8GRNC A ERPB2 8GRNRAC A LRPB2 8GRNC A LRPB2 8GRNRAC A Page 6 97924C Rev J 07 16 Figure 10 Fountain Body Assembly Figure 11 Push Button Assembly 17 3 3 4 4 4 6 7...

Страница 7: ...Panel Drain Plug 1 1 2 Poly Tubing Cut To Length Kit Tee 1 4 3 Pack Gasket Drain Assy Drain Tailpipe Screw 5 16 18 x 1 00 HHMS PARTS LIST ITEM NO PART NO DESCRIPTION Installation Package The component...

Отзывы: