background image

ERPB2-8C, ERPB2-8RAC, ERPBV2-8C, ERPBV2-8RAC, LRPB2-8C, LRPB2-8RAC, ERPB2-8C*2C, ERPB2-8C*3C

ERPB2-8GRNC*A, ERPB2-8GRNRAC*A, LRPB2-8GRNC*A, LRPB2-8GRNRAC*A 

97924C  (Rev. J - 07/16)

Page 1

      ERPB2-8C                                                               ERPB2-8RAC 

SWIRLFLO

®

 Refrigerated fountains with FLEXI-GUARD

®

INSTALLATION, CARE & USE MANUAL

 

Review these instructions before beginning installation. Be sure that installation  

 

 

conforms to all plumbing, electrical and other applicable codes.

  When installation is complete, ensure these instructions are left in the plastic bag 

 

 

provided inside the installed unit for future reference.

  Service to be performed by authorized service personnel only.

INSTALLER

NOTE:  It is common practice to ground electrical hardware such as telephones, computers and other devices 

to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which 

results in an “electrolysis” effect occurring in the fountain. This may result in water which has a 

metallic taste to it or has a noticeable increase in the metallic content of the water.

 

When inspecting plumbing circuit, remember the line may be grounded some distance from the 

installation, and may occur outside the building or area in which the unit is being installed.

 

This condition can be avoided (in most cases) by using recommended materials during installation. 

Any drain fittings provided by the installer should be made of 

plastic

 which will 

electronically isolate

 

the fountain from the remainder of the building’s plumbing circuits.

Содержание SWIRLFLO ERPB2-8C

Страница 1: ...It is common practice to ground electrical hardware such as telephones computers and other devices to available water lines This can however cause electrical feedback in the plumbing circuit which res...

Страница 2: ...B2 8C 3C ERPB2 8GRNC A ERPB2 8GRNRAC A LRPB2 8GRNC A LRPB2 8GRNRAC A Page 2 97924C Rev J 07 16 LEGEND A 1 4 O D Tube Water Outlet Connection B 3 8 O D Tube Water Inlet Connection C 1 1 4 Waste Tube D...

Страница 3: ...ushing it until it reaches a positive stop approximately 3 4 19mm on the marked chiller inlet port Connect building supply line to strainer See Figure 3 Caution DO NOT SOLDER tubes inserted into the s...

Страница 4: ...the chiller 1 4 O D copper tube Install a 1 4 x 1 4 tee provided on the marked chiller outlet port Insert the 1 4 poly tubing coming from the fountain into the union CAUTION DO NOT SOLDER tubes insert...

Страница 5: ...BUBBLER DETAIL NOTE When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten Basin Figure 8 Bubbler Details 1 or 2 Locknut 10A or 10B Bas...

Страница 6: ...PB2 8RAC ERPB2 8C 2C ERPB2 8C 3C ERPB2 8GRNC A ERPB2 8GRNRAC A LRPB2 8GRNC A LRPB2 8GRNRAC A Page 6 97924C Rev J 07 16 Figure 10 Fountain Body Assembly Figure 11 Push Button Assembly 17 3 3 4 4 4 6 7...

Страница 7: ...Panel Drain Plug 1 1 2 Poly Tubing Cut To Length Kit Tee 1 4 3 Pack Gasket Drain Assy Drain Tailpipe Screw 5 16 18 x 1 00 HHMS PARTS LIST ITEM NO PART NO DESCRIPTION Installation Package The component...

Отзывы: