background image

Elkay Manufacturing Company 

10 

 

Countertop  

 

Installation Manual (2000000029 Rev. B - 01/22)

2.  Prepare the water inlet line to connect to the Remote 

Chiller unit. 

 

3.  Place the black insulation tubing over the 3/8" blue 

water tubing.

4.  Connect the 3/8" poly tube from the potable water 

source to the IN port of the filter.

a.  Connect the pressure regulator and shut-off valve 

to the filter inlet.

b.  Firmly insert the filter into the filter head, then twist 

the filter clockwise to secure. 

 

5.  Fill the ice bank in the Remote Chiller unit.

a.  Make sure the Remote Chiller's power switch is in 

the OFF position.

b.  Remove four Phillips screws and the cover from 

the back of the chiller.  

Note:

  This reveals the overflow tube.

 

 

c.  Remove the plug from the fill port of the ice bank. 

Insert the 3/8" water line into the water inlet port to 

fill the ice bank of the Remote Chiller. 

 

d.  Note: 

An overfill port is located behind the panel. 

This panel can be removed to access the overflow 

port but it is not necessary if care is used when 

filling the tank

 

Slowly fill the ice bank until the water reaches the 

maximum fill line on the overflow tube. Do not over 

fill the ice bank of the Remote Chiller.

 

 

e.  Once the Remote Chiller is filled, remove the water 

line and replace the plug. 

Note:

  Residual water may spill out of the fill port. 

This is completely normal. Wipe the residual spilled 

water with a dry cloth.

6.  Connect the 3/8" water supply line to the IN WATER 

port on the Remote Chiller. 

 

Remote

 Chiller

Filter

Remote Chiller

Water Inlet port

Shut-off valve

Potable water 

source

Wall

Filter

Pressure Regulator

Remote Chiller

Remote Chiller

Содержание smartwell SW1806CR

Страница 1: ...Smartwell Countertop Beverage Dispenser with Remote Chiller Model SW1806CR Installation Manual Beverage Dispenser WARNING Read the instructions in this manual and retain for future reference ...

Страница 2: ...This manual contains step by step installation instructions for the Elkay Smartwell Countertop beverage dispenser with Remote Chiller A separate Use and Care manual contains the operating instructions The Elkay Smartwell Countertop is a filtered water dispenser that gives users the option to create their own custom beverages using a touch screen on the unit or a mobile device for touchless operati...

Страница 3: ...property damage can result if instructions are not followed SAFETY INSTRUCTIONS Safety instructions or equivalent signs indicate specific safety related instructions or procedures Note Contains additional information important to a procedure 2 4 Personal Safety WARNING These warnings indicate a potentially hazardous situation which if not avoided could result in serious injury or death Follow all ...

Страница 4: ...e CO2 tank supplier including but not limited to Indirect eye contact with CO2 gas may cause mild irritation Direct eye contact with the liquefied gas can freeze the eye causing permanent eye damage or blindness CO2 gas displaces oxygen Make sure there are no CO2 gas leaks in any part of the Smartwell beverage system Direct contact with the liquefied gas can chill or freeze the skin frostbite Trip...

Страница 5: ...standard 120 Volts electric wall receptacle is required The unit must be close enough to socket that the supplied power cord reaches without stress or stretching NOTICE DO NOT connect the unit to a power strip and DO NOT use an extension cord 2 A minimum 20 Amp GFCI outlet on a dedicated circuit is recommended with a minimum current of 5 amps Prior to installation ensure that it is possible to dis...

Страница 6: ...ell Cabinet Optional Countertop Dispenser Recommended Hole Dimension Note 18 wide cabinet can store up to a 5 lb CO2 tank 24 wide cabinet can store up to a 20 lb CO2 tank 20 lb CO2 tank shown for reference Compatible with smaller tank sizes Depth of the kitchen cabinet should be at least 22 inches Refer P N 2000000401 for ventilation instruction sheet template Kitchen Cabinet Toe Kick Ventilation ...

Страница 7: ...70 1 6 Filter 51299C 1 7 Power Cord 1000004819 1 8 Ethernet Cable 15 feet 1000005025 1 9 Wi Fi Extender 1000005047 1 10 CO2 Bottle Wall Mounting Bracket 1000005199 1 11 50 psi Water Pressure Regulator 1000002467 1 12 Elbow Fitting 3 8 stem x 3 8 tube 70818C 2 13 Filter Head Assembly 1000006192 1 Countertop Dispenser 1 Remote Chiller Boxed Separately 2000000072 1 Pouch Tray 1000005882 1 Drip Tray 1...

Страница 8: ...wise to secure b Using 3 8 water tubing make a connection from the water source to the inlet side of the water pressure regulator c With 3 8 water tubing connect the outlet of the water pressure regulator to the shut off valve d With 3 8 water tubing connect the other end of the shut off valve to the IN port of the water filter e Connect a length of 3 8 water tubing to the OUT port of the water fi...

Страница 9: ...ng the chiller and enclosure See the separate document Smartwell Chiller Ventilation Instructions which includes templates for drilling the required ventilation holes for the chiller 1 Remove 4 screws from the grate on the back of the chiller 2 Place the chiller duct into position as shown aligning the 4 holes with the previous location of the 4 screws removed from the grate 3 Replace the 4 screws...

Страница 10: ...e c Remove the plug from the fill port of the ice bank Insert the 3 8 water line into the water inlet port to fill the ice bank of the Remote Chiller d Note An overfill port is located behind the panel This panel can be removed to access the overflow port but it is not necessary if care is used when filling the tank Slowly fill the ice bank until the water reaches the maximum fill line on the over...

Страница 11: ...let port of the Remote Chiller to the still water inlet port of the Countertop unit 2 Connect the 3 8 poly tube from the sparkling water outlet port of Remote Chiller to the CO2 port of the Countertop unit 5 7 Internet 1 Connect an Ethernet cable from your network into the back of the Countertop dispenser or skip to step 2 if connecting via Wi Fi 2 Connect the unit to the supplied Wi Fi extender a...

Страница 12: ...Initial Setup 1 Once the Countertop unit main power switch has been flipped to ON a loading screen followed by the Welcome screen will appear 2 Select either Wi Fi or Ethernet connection and press continue a If Wi Fi connection is selected the Wi Fi Netgear screen will open Please follow the manufacturer s directions to set up Note Smartwell uses HTTPS port 443 AMQP port 5671 to allow communicatio...

Страница 13: ...installed 5 Depending on whether or not the unit is connected to the Internet one of the following screens will appear The left hand screen will appear if the unit is not connected to the Internet Select the appropriate date and time zone settings then press Save The right hand screen will appear if the unit is connected to the Internet Select the appropriate time zone settings then press Save 6 A...

Страница 14: ... they have clicked onto the pump drive holder ensuring it is securely fastened 4 Fully insert the stainless steel nibs into the holes of the manifold taking care to hold by the tubes to avoid contamination Note Check and ensure the flow straightener is snapped properly 5 Select the flavor or enhancement for each slot Choose the MM DD YY from the Best by date slot and select the date Press save 6 S...

Страница 15: ...nes 1 Open the water supply valve and purge the trapped air from the water line Note To flush out trapped air allow water to run continuously until the flow is free of air bubbles NOTICE Water pressure that does not meet the minimum pressure requirement of 40 psi can cause damage to the internal components Low pressure may also affect the performance of the unit and the taste of the beverage a Pla...

Страница 16: ...ation of flavor in the beverage low medium or high This setting is based on user preferences and the default setting is MEDIUM If more flavor is desired select the HIGH setting d Determine and enter the flow rate for the Still Water and the flow rate for the Sparkling Water 1 Place a large graduated measuring cup at least 32 fl oz under the dispenser nozzle 2 Using a stop watch measure the volume ...

Страница 17: ... 3 Unit Diagnostics screen will appear a Press start test to examine the functionality of Motors Water solenoids Temperature Fan Speed Alcove lighting Firewall setting Cloud Communication Internet Speed b Press stop test to complete the unit diagnostics 6 6 Check for Updates The Smartwell unit must be connected to the Internet to receive automatic system updates Follow the next steps to manually c...

Страница 18: ...ally check for software updates 3 The unit will search for system updates If your system is not up to date the system will begin automatically updating to the latest software If there is no update required press close to exit ELKAY MANUFACTURING COMPANY 1333 BUTTERFIELD ROAD SUITE 200 DOWNERS GROVE IL 60515 630 574 8484 www elkay com FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 834 4816 ...