background image

Page 2

1000005817

1000005818  (Rev. A - 06/20)

WATER  COOLER  PREPARATION

 

Remove Lower wrapper on the cooler by removing the (4) screws using a 5/16 nut driver

 

Shut off water to the cooler

 

Remove water pressure by pressing on any of the cooler push bars until no water comes out of the bubbler

 

Unplug the water cooler

 

Remove the P-trap from the cooler drain

1.  Remove the (4) screws – 2 per side on the upper shroud using the Torx bit or Allen 

Wrench. (See Fig. 1) Note: The kit is for refrigerated units only.

2.  Take a black marker and mark the water line where it enters the base of the evaporator. 

This will ensure the water line is reinserted fully later. Fig. 2 & 3

                        Fig. 1

                        Fig. 4

                        Fig. 2

                         Fig. 3

3.  Remove the water line from the evaporator. Have a bucket ready to catch water 

coming from the evaporator.

4.  Lift the basin shroud assembly, tilting forward towards the front of the water cooler and 

unplug the two switch wires. One on the solenoid and one on the cold control. Once 

both wires are free lift the assembly completely off.

5.  Turn the basin/shroud assembly over on a table so that it is sitting on the basin. 
6.  Locate the serial number on the data label and write it down in permanent marker on 

the blank label on the bottom of the new shroud.

7.  Loosen the clamp on the drain and remove it and the plastic drain.
8.  Remove the basin from the shroud by removing the four screws with the Torx bit or 

Allen Wrench. 

Note: If your shroud has a regulator installed it will need to be 

removed too.

9.  Place the new shroud on the basin and attach it using the screws removed.  

Note: If a regulator was removed from the old shroud it will need to be inserted 

in the new shroud.

10. Insert the clamp and plastic drain into the rubber drain boot and tighten.
11. Using a Flat head screwdriver remove the plastic cap covering the electricals on the 

compressor. Fig. 4

Содержание RETROFIT EZS Series

Страница 1: ...R MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER...

Страница 2: ...tilting forward towards the front of the water cooler and unplug the two switch wires One on the solenoid and one on the cold control Once both wires are free lift the assembly completely off 5 Turn...

Страница 3: ...compressor relay and the black wire from the overload Leave the fan wires connected Fig 5 6 13 Remove the power cord ground connection on the frame using the nut driver Keep this screw it will be need...

Страница 4: ...9 17 Squeeze the strain relief and place in the slot in the bracket that the old power cord was removed Push up until it locks into place Fig 10 Fig 10 Fig 9 14 Using pliers squeeze the strain relief...

Страница 5: ...old ground wire was connected Tighten the screw so that the terminal will not turn To make sure that the grounding connection is secure use a multi meter and check for continuity Place one probe on th...

Страница 6: ...ains the same 23 Place the basin shroud assembly back on to the cooler frame and connect the sensor wires Connect the black wire to the piggyback terminal on the solenoid the red wire on the open term...

Страница 7: ...up to the line that was drawn on the water line earlier Spin the fan blade to ensure it spins freely and there are not any wires or that the water line is not in it Place the 4 screws back in to hold...

Отзывы: