background image

Page 1

1000005818  (Rev. A - 06/20)

1000005817

INSTALLATION MANUAL

To insure you install this Kit easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK 

YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND 

OTHER APPLICABLE CODES.

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY.  

ALL SERVICE TO BE PERFORMED BY AN

 AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM 

THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE 

WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN 

FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE 

FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION 

AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).

INSTALLER

TOOLS REQUIRED

BUT NOT PROVIDED:

GLOVES

SAFETY GLASSES

NEEDLE NOSE AND REGULAR PLIERS

¼ AND 5/16 NUT DRIVERS

FLAT HEAD SCREWDRIVER 

T-20 TORX BIT OR 7/64 ALLEN WRENCH

BLACK MARKER

BUCKET

MULTI-METER

RETROFIT KIT EZS TO EZO

Содержание RETROFIT EZS Series

Страница 1: ...R MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER...

Страница 2: ...tilting forward towards the front of the water cooler and unplug the two switch wires One on the solenoid and one on the cold control Once both wires are free lift the assembly completely off 5 Turn...

Страница 3: ...compressor relay and the black wire from the overload Leave the fan wires connected Fig 5 6 13 Remove the power cord ground connection on the frame using the nut driver Keep this screw it will be need...

Страница 4: ...9 17 Squeeze the strain relief and place in the slot in the bracket that the old power cord was removed Push up until it locks into place Fig 10 Fig 10 Fig 9 14 Using pliers squeeze the strain relief...

Страница 5: ...old ground wire was connected Tighten the screw so that the terminal will not turn To make sure that the grounding connection is secure use a multi meter and check for continuity Place one probe on th...

Страница 6: ...ains the same 23 Place the basin shroud assembly back on to the cooler frame and connect the sensor wires Connect the black wire to the piggyback terminal on the solenoid the red wire on the open term...

Страница 7: ...up to the line that was drawn on the water line earlier Spin the fan blade to ensure it spins freely and there are not any wires or that the water line is not in it Place the 4 screws back in to hold...