EZWSR*1C, *2C    LZWSR*1C, *2C

1000001734  (Rev. K - 04/18)

     Bi-Level MODIFICATION OF WATER SYSTEM

    NOTE:

 Bi-Level water systems are already plumbed for pressurization.

      STANDARD Bi-Level MODELS

Follow instruction 2 thru 4 under “Pressurization of water system” to attach filter to water system. The non-refrigerated side must be removed from the wall in 

order to remove the basin assy. and install the filter head assy.

1) Remove the Bi-Level Cover Plate from the right hand side of the non-refrigerated unit in order to access the rear Basin Assy. screw.

2) Cut  poly tube “H” between the existing tee and the solenoid valve of the L.H. unit (See Fig. 6A or 6C).

3) Insert supplied Tee in water line “H” where it was just cut (See Fig. 7A or 7C).   

   

      

Bi-Level Versatile MODELS

Follow instruction 2 thru 4 under “Pressurization of water system” to attach filter to water system. The non refrigerated side must be removed from the wall in 

order to remove the basin assy. and install the filter head assy.

1) Remove the Bi-Level Cover Plate from the left hand side of the refrigerated unit in order to access the rear Basin Assy. screw (See Fig 8).

2) Cut poly tube “H” approximately 3” from the left side of the existing tee.

3) Insert supplied tee in water line “H” where it was just cut.

WATER  COOLER  PREPARATION

1) Remove lower front panel of watercooler by removing the four (4) screws from 

the bottom of cooler. (See Fig. 1) NOTE: For Bi-Level Models the Bottle Filling 

Unit can be mounted to the higher or lower unit. Both lower front panels and basin 

assemblies will need to be removed.

1a) For units with model no’s. ending with 1, 1A, 2 or 3 these units will need to be 

removed from the wall in order to remove the basin assembly(s).

2)

 

Power OFF circuit that the water cooler is connected to by switching the 

circuit breaker to the “OFF” position or by removing the fuse to the circuit. 

Remove the water cooler plug from the outlet and shut off water supply.

3) Remove Basin Assembly by loosening four (4) screws two on each side of 

cooler as shown in Fig. 8. Disconnect water line “A” from bubbler at the 

evaporator tank (See Fig. 6). NOTE: When disconnecting water lines use a 

container to catch any water running out of the lines.  Disconnect basin assembly 

from drain trap. Lift basin assembly straight up to remove, and disconnect two 

wires from push bar switches. (Note: This will allow easier assembly of water filter 

to unit and pressurization of the unit.)

5a) For units referenced in step “1a”.  Remove Basin Assembly by 

loosening four (4) screws two on each side of cooler as shown in Fig. 8.  Remove 

2 screws from top back of unit to remove the “L” bracket. Remove 1 screw from 

left side of cross brace in front of unit that retains the drain support.  Disconnect 

water line “A” from regulator at the evaporator tank (See Fig. 6B). NOTE: When 

disconnecting water lines use a container to catch any water running out of the lines.  

Disconnect basin assembly from drain trap. Lift basin assembly straight up to 

remove, and disconnect two wires from push bar switches. 

(Note: This will allow 

easier assembly of water filter to unit and pressurization of the unit.)

 

EWF3000 WATERSENTRY  PLUS FILTER INSTALLATION

NOTICE:  Do not use with water that is microbiologically unsafe or of un-

known quality without adequate disinfection before or after the system.

1) These filter kits must be installed in compliance with all state and local laws 

and regulations governing the installation and use of this product.  Maximum inlet 

water temperature 100°F (38°C).

2) See filter instructions for filter assembly. Insert 3/8” elbow fitting into the inlet 

side of filter head, insert 1/4” poly tube or 1/4” x 90° elbow into outlet side of filter 

head prior to mounting the filter head assembly into the cooler.

3) Mount filter head as shown in Fig. 9, using the filter mounting bracket and 

screws supplied. For Bi-Level units the filter must be mounted to the L.H. 

non-refrigerated unit at the same location as shown in Fig. 9. 

   PRESSURIZATION OF WATER SYSTEM

NOTE: This procedure MUST be performed on ALL SINGLE EZ WATER 

COOLERS

 or the bottle filling unit 

WILL NOT perform properly!

1) Remove water inlet (B) and outlet (C) from solenoid valve (See Fig. 6 or 6B). 

NOTE: When disconnecting water lines use a container to catch any water run-

ning out of the lines.

2) CAUTION:   If supply pressure will ever exceed 100 psi, install a pressure 

regulator to limit the inlet pressure to the filter to 100 psi or below.  

DO NOT ATTACH HOT WATER LINE TO FILTER. 

To make connections on the 

filter head, loosen locknut. Push the tube end past both o-rings to a positive stop 

in the filter head recess - approx. 1”, locknut may have to be backed out a little 

more.  Screw the locknut hand tight to seal (See Fig. 10).  Ends of tubing must be 

cut square and free of burrs and sharp ends that could cut or nick the o-rings.

3) Connect the outlet of the filter to the inlet of the evaporator using the 1/4” O.D. 

poly tubing and 1/4” union supplied (See Fig. 7 or 7B).

4) Cut a 12” long piece of poly tube (be sure to insulate poly tube with supplied 

insulation tubing) and insert one end into the outlet side of the evaporator “D” 

(See Fig. 7 or 7B), connect Tee to other end of tube.

5) Cut a 12” long piece of poly tube (be sure to insulate poly tube with supplied 

insulation tubing) and insert into the Tee and the other end into the inlet side of 

the solenoid valve “E” (See fig. 7 or 7B).

Fig. 1

LOWER COVER

SCREWS

Содержание LZWSRK-EZH2O

Страница 1: ...EPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY T...

Страница 2: ...o remove the L bracket Remove 1 screw from left side of cross brace in front of unit that retains the drain support Disconnect water line A from regulator at the evaporator tank See Fig 6B NOTE When disconnecting water lines use a container to catch any water running out of the lines Disconnect basin assembly from drain trap Lift basin assembly straight up to remove and disconnect two wires from p...

Страница 3: ...ION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAM...

Страница 4: ... DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES 3 DE SUMINISTRO ELÉCTRICO...

Страница 5: ...FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES...

Страница 6: ... STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES 3 DE SUMINISTRO ELÉCTRICO BOÎTE...

Страница 7: ...3 8 To 1 4 Union Tube Insulation Tube Insulation Tee Fig 6A Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve E F G D Fig 7A EZ Bi Level Plumbing Diagram after Bottle Filler Water Line Addition R H Refrig unit L H Non Refrig unit Evaporator Bubbler Solenoid Valve Water Inlet H Solenoid Valve ...

Страница 8: ...e 3 8 Water Inlet D E F Fig 7B Regulator Tube Insulation 3 8 To 1 4 Union Fig 6C Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve Regulator Regulator EZ Bi Level Plumbing Diagram after Bottle Filler Water Line Addition Fig 7C Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from...

Страница 9: ...urized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve Tee 3 8 Water Inlet D E F Fig 7D Solenoid Valve Solenoid Valve 1 4 Union Tube Insulation Tube Insulation Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line ...

Страница 10: ...er Inlet D E F Fig 7F 1 4 Union Regulator Fig 6G Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve Regulator Regulator EZ Bi Level Plumbing Diagram after Filter Installation Bottle Filler Water Line Addition Fig 7G Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from Bottle Fill...

Страница 11: ...sembly back to the purple or yellow piggyback terminal on the solenoid valve Connect the other black wire from the pushbar assembly to the piggyback on the cold control Feed the purple and or yellow wire s up through basin hole and reattach drain to the trap and reinstall drain support screw to front cross brace Reinstall L bracket to top back of unit with the 2 screws it was mounted with Retighte...

Страница 12: ...OAD COLD CONTROL SOLENOID VALVE GREEN BLK GND PURPLE OR YELLOW JUMPER MAIN BOARD I R BOARD LED BOARD GND SOLENOID POWERCORD PIGGY BACK TERMINAL ON POWER CORD FOUR PIN CONNECTOR FIVE PIN CONNECTOR CONNECTOR FROM POWER CORD LINE VOLTAGE SMOOTH BLACK GROUND GREEN NEUTRAL WHITE RIBBED CONNECTOR VIOLET TO UNIT SOLENOID YELLOW TO BILEVEL SOLENOID YELLOW CONNECTOR VIOLET GN WHITE RED PURPLE JUMPER OR YEL...

Страница 13: ...working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protruding from the wall See Fig 14 mounting plate installed on wall Make sure round boss in gasket fits in hole of basin 11 Once Bottle Filler is installed on wall plate tabs waterline wire s and power cord are installed properly push top of Bottle Filler...

Страница 14: ...Page 14 EZWSR 1C 2C LZWSR 1C 2C 1000001734 Rev K 04 18 BOTTLE FILLER GASKET Fig 15 Fig 16 ...

Страница 15: ... to where the smooth black wire was connected 4 Add the male to male adapter to the smooth wire removed in step 3 5 Connect the smooth black wire with male adapter to the switch wire from pushbar removed in step 2 6 Reconnect power to all units Verify bottle filler counter advances only when water is flowing 7 Once unit tests out install lower panels back on water cooler Units are ready for use RE...

Страница 16: ...01734 Rev K 04 18 PLUMBING DIAGRAMS VERSATILE BI LEVEL Barb capped when not used Barb capped when not used Barb capped when not used Barb capped when not used Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain ...

Страница 17: ...will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TY...

Страница 18: ... hole see Fig 18 3 Drill two 3 16 dia hole at location B shown in Fig 18 4 Remove Filter bracket from filter assembly and reinstall as shown in Fig 19 Be sure the 3 8 water inlet is facing out 5 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 6 Install filter assembly to bottom of cooler as shown in Fig 19 wi...

Страница 19: ...t IR Sensor 115V Kit Solenoid Valve Replacement 115V Kit Solenoid Valve Replacement 220V Kit Aerator Replacement Kit Top Cover Replacement Kit Drain Tower Basin Gasket Kit Hardware Waterway Parts Kit LZ Filter Mounting Cover L Kit LZ Filter Mounting Cover S Kit Retro Filter Mounting Kit Basin Replacement Kit Bottle Filler Drain Kit Drain Replacement REPLACEMENT PART KITS PART NO 1 2 3 2 WATER FILT...

Отзывы: