background image

Page 11

1000001734  (Rev. K- 04/18)

EZWSR*1C, *2C    LZWSR*1C, *2C  

      BASIN ASSEMBLY  PREPARATION

1) 

Remove (4) screw

s from basin/shroud assembly. Separate basin from shroud.

2) Remove bubbler.

3) 

Install bubbler

 on new basin.

4) 

Remove drain tail piece

 from rubber boot that is attached to the shroud.

5) 

Assemble shroud 

onto new basin.

6) 

Install branch line

 drain tail piece to rubber boot. Connect hose clamp and drain hose to branch line on tail piece and tighten hose clamp.

7) 

For Single Model installations:

 Attach the purple wire (supplied),  on to the open terminal of the solenoid valve.

7a) 

For Bi-Level Model installations:

 Attach the purple wire (supplied), on to the open terminal of the solenoid valve to the unit that the basin hole

    was punched in for the Bottle Filling Station.  Attach the yellow wire (supplied), on to the open terminal of the solenoid valve of the other unit.

8) 

Reassemble Basin Assembly

 back on to unit. Connect the bubbler water line to the outlet side of the solenoid valve “F” (See Fig. 7),  be sure to 

  reconnect the black wire from the pushbar assembly back to the purple or yellow piggyback terminal on the solenoid valve. and the other black wire back

  to the cold control or power cord (non-refrigerated unit),  feed the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap. 

  Retighten the 4 screws two per side (See Fig. 8).

     FOR UNITS WITH MODEL NO’S. ENDING IN 1, 1A, 2, & 3

8a) 

Remove the white wire

 from the cold control and connect it to the power cord white wire. Reassemble Basin Assembly back on to unit. Connect the 

regulator water line to the outlet side of the solenoid valve “F” (See Fig. 7B),  be sure to reconnect one black wire from the pushbar assembly back to the 

purple or yellow piggyback terminal on the solenoid valve. Connect the other black wire from the pushbar assembly to the piggyback on the cold control.  

Feed the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap and reinstall drain support screw to front cross brace.  Reinstall 

“L” bracket to top back of unit with  the 2 screws it was mounted with. Retighten the 4 screws two per side (see Fig. 8).

      ALL STANDARD Bi-Level MODELS

After completing instructions 1 thru 8 or 8a from above on the non-refrigerated side. Install filter head assembly per previous installation instructions and 

reinstall basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube (or regulator tube) to solenoid valve and reinstall the Bi-Level cover plate 

to the left side of the unit.  Reinstall non-refrigerated unit to wall and reinstall drain.

      ALL Bi-Level Versatile MODELS

After completing instructions 1 thru 8 or 8a from above on the refrigerated side. Install filter head assembly per previous installation instructions and reinstall 

basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube (or regulator tube) to solenoid valve and reinstall the Bi-Level cover plate to the 
left side of the unit. Reinstall non-refrigerated unit to wall and reinstall drain.

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

Fig. 8

SCREWS

SCREWS

BASIN ASSEMBLY

Fig. 9

Basin Assembly Removal

EWF3000 Filter Location

FILTER ASSEMBLY

SCREWS

Fig. 10

 

Note:  Screw the locknut hand tight to seal

Fig. 11

Содержание LZWSRK-EZH2O

Страница 1: ...EPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY T...

Страница 2: ...o remove the L bracket Remove 1 screw from left side of cross brace in front of unit that retains the drain support Disconnect water line A from regulator at the evaporator tank See Fig 6B NOTE When disconnecting water lines use a container to catch any water running out of the lines Disconnect basin assembly from drain trap Lift basin assembly straight up to remove and disconnect two wires from p...

Страница 3: ...ION FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAM...

Страница 4: ... DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES 3 DE SUMINISTRO ELÉCTRICO...

Страница 5: ...FOR WASTE OUTLET 1 1 2 O D DRAIN STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES...

Страница 6: ... STUB 2 IN OUT FROM WALL UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA DE 1 1 2 DE DIÁMETRO El TALONARIO 2 FUERA DE PARED EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D E 1 1 2 DE SORTIE D EAU STUB 2 HORS DU MUR C 1 1 2 TRAP NOT FURNISHED PURGADOR DE 1 1 2 NO PROPORCIONADO SIPHON 1 1 2 NON FOURNI D ELECTRICAL SUPPLY 3 WIRE RECESSED BOX CAJA RECESIVA DE ALAMBRES 3 DE SUMINISTRO ELÉCTRICO BOÎTE...

Страница 7: ...3 8 To 1 4 Union Tube Insulation Tube Insulation Tee Fig 6A Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve E F G D Fig 7A EZ Bi Level Plumbing Diagram after Bottle Filler Water Line Addition R H Refrig unit L H Non Refrig unit Evaporator Bubbler Solenoid Valve Water Inlet H Solenoid Valve ...

Страница 8: ...e 3 8 Water Inlet D E F Fig 7B Regulator Tube Insulation 3 8 To 1 4 Union Fig 6C Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve Regulator Regulator EZ Bi Level Plumbing Diagram after Bottle Filler Water Line Addition Fig 7C Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from...

Страница 9: ...urized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve Tee 3 8 Water Inlet D E F Fig 7D Solenoid Valve Solenoid Valve 1 4 Union Tube Insulation Tube Insulation Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line ...

Страница 10: ...er Inlet D E F Fig 7F 1 4 Union Regulator Fig 6G Standard EZ Bi Level Pressurized Plumbing Diagram R H Refrig unit L H Non Refrig unit Evaporator Bubbler Water Inlet Bubbler H Solenoid Valve Solenoid Valve Regulator Regulator EZ Bi Level Plumbing Diagram after Filter Installation Bottle Filler Water Line Addition Fig 7G Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from Bottle Fill...

Страница 11: ...sembly back to the purple or yellow piggyback terminal on the solenoid valve Connect the other black wire from the pushbar assembly to the piggyback on the cold control Feed the purple and or yellow wire s up through basin hole and reattach drain to the trap and reinstall drain support screw to front cross brace Reinstall L bracket to top back of unit with the 2 screws it was mounted with Retighte...

Страница 12: ...OAD COLD CONTROL SOLENOID VALVE GREEN BLK GND PURPLE OR YELLOW JUMPER MAIN BOARD I R BOARD LED BOARD GND SOLENOID POWERCORD PIGGY BACK TERMINAL ON POWER CORD FOUR PIN CONNECTOR FIVE PIN CONNECTOR CONNECTOR FROM POWER CORD LINE VOLTAGE SMOOTH BLACK GROUND GREEN NEUTRAL WHITE RIBBED CONNECTOR VIOLET TO UNIT SOLENOID YELLOW TO BILEVEL SOLENOID YELLOW CONNECTOR VIOLET GN WHITE RED PURPLE JUMPER OR YEL...

Страница 13: ...working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protruding from the wall See Fig 14 mounting plate installed on wall Make sure round boss in gasket fits in hole of basin 11 Once Bottle Filler is installed on wall plate tabs waterline wire s and power cord are installed properly push top of Bottle Filler...

Страница 14: ...Page 14 EZWSR 1C 2C LZWSR 1C 2C 1000001734 Rev K 04 18 BOTTLE FILLER GASKET Fig 15 Fig 16 ...

Страница 15: ... to where the smooth black wire was connected 4 Add the male to male adapter to the smooth wire removed in step 3 5 Connect the smooth black wire with male adapter to the switch wire from pushbar removed in step 2 6 Reconnect power to all units Verify bottle filler counter advances only when water is flowing 7 Once unit tests out install lower panels back on water cooler Units are ready for use RE...

Страница 16: ...01734 Rev K 04 18 PLUMBING DIAGRAMS VERSATILE BI LEVEL Barb capped when not used Barb capped when not used Barb capped when not used Barb capped when not used Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain ...

Страница 17: ...will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TY...

Страница 18: ... hole see Fig 18 3 Drill two 3 16 dia hole at location B shown in Fig 18 4 Remove Filter bracket from filter assembly and reinstall as shown in Fig 19 Be sure the 3 8 water inlet is facing out 5 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 6 Install filter assembly to bottom of cooler as shown in Fig 19 wi...

Страница 19: ...t IR Sensor 115V Kit Solenoid Valve Replacement 115V Kit Solenoid Valve Replacement 220V Kit Aerator Replacement Kit Top Cover Replacement Kit Drain Tower Basin Gasket Kit Hardware Waterway Parts Kit LZ Filter Mounting Cover L Kit LZ Filter Mounting Cover S Kit Retro Filter Mounting Kit Basin Replacement Kit Bottle Filler Drain Kit Drain Replacement REPLACEMENT PART KITS PART NO 1 2 3 2 WATER FILT...

Отзывы: