Page 11
1000001734 (Rev. K- 04/18)
EZWSR*1C, *2C LZWSR*1C, *2C
BASIN ASSEMBLY PREPARATION
1)
Remove (4) screw
s from basin/shroud assembly. Separate basin from shroud.
2) Remove bubbler.
3)
Install bubbler
on new basin.
4)
Remove drain tail piece
from rubber boot that is attached to the shroud.
5)
Assemble shroud
onto new basin.
6)
Install branch line
drain tail piece to rubber boot. Connect hose clamp and drain hose to branch line on tail piece and tighten hose clamp.
7)
For Single Model installations:
Attach the purple wire (supplied), on to the open terminal of the solenoid valve.
7a)
For Bi-Level Model installations:
Attach the purple wire (supplied), on to the open terminal of the solenoid valve to the unit that the basin hole
was punched in for the Bottle Filling Station. Attach the yellow wire (supplied), on to the open terminal of the solenoid valve of the other unit.
8)
Reassemble Basin Assembly
back on to unit. Connect the bubbler water line to the outlet side of the solenoid valve “F” (See Fig. 7), be sure to
reconnect the black wire from the pushbar assembly back to the purple or yellow piggyback terminal on the solenoid valve. and the other black wire back
to the cold control or power cord (non-refrigerated unit), feed the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap.
Retighten the 4 screws two per side (See Fig. 8).
FOR UNITS WITH MODEL NO’S. ENDING IN 1, 1A, 2, & 3
8a)
Remove the white wire
from the cold control and connect it to the power cord white wire. Reassemble Basin Assembly back on to unit. Connect the
regulator water line to the outlet side of the solenoid valve “F” (See Fig. 7B), be sure to reconnect one black wire from the pushbar assembly back to the
purple or yellow piggyback terminal on the solenoid valve. Connect the other black wire from the pushbar assembly to the piggyback on the cold control.
Feed the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap and reinstall drain support screw to front cross brace. Reinstall
“L” bracket to top back of unit with the 2 screws it was mounted with. Retighten the 4 screws two per side (see Fig. 8).
ALL STANDARD Bi-Level MODELS
After completing instructions 1 thru 8 or 8a from above on the non-refrigerated side. Install filter head assembly per previous installation instructions and
reinstall basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube (or regulator tube) to solenoid valve and reinstall the Bi-Level cover plate
to the left side of the unit. Reinstall non-refrigerated unit to wall and reinstall drain.
ALL Bi-Level Versatile MODELS
After completing instructions 1 thru 8 or 8a from above on the refrigerated side. Install filter head assembly per previous installation instructions and reinstall
basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube (or regulator tube) to solenoid valve and reinstall the Bi-Level cover plate to the
left side of the unit. Reinstall non-refrigerated unit to wall and reinstall drain.
B
C
A
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
Fig. 8
SCREWS
SCREWS
BASIN ASSEMBLY
Fig. 9
Basin Assembly Removal
EWF3000 Filter Location
FILTER ASSEMBLY
SCREWS
Fig. 10
Note: Screw the locknut hand tight to seal
Fig. 11