background image

Page 3

98518C  (Rev. B - 2/10)

LZWSR*1A

Fig. 3

SCREWS

SCREWS

BASIN ASSEMBLY

Fig. 4

Basin Assembly Removal

EWF3000 Filter Location

FILTER ASSEMBLY

SCREWS

BASIN ASSEMBLY  PREPARATION

1) Center punch 1/2” hole location on basin prior to drilling the hole in top of cooler basin using an adequete drill and 1/2” drill bit capable of drilling
through stainless steel (See FIG. 2).
2) Locate 1-3/8” knockout punch tool (provided).  Unscrew the top half from the bottom half of the tool.
3) With one hand holding the bottom half, and the other hand holding the top half of the punch, insert the top half bolt through the 1/2” hole in basin,
then reach inside the basin assembly underneath the cooler basin with the bottom half and thread it on to the top half bolt. Tighten bottom half on punch
until finger tight.
4) Using 3/4” wrench or crecent wrench tighten the bolt on top half of punch until basin gives way creating the larger hole. Note tool will turn hard.
5) Once hole is made tool may be discarded.
6) Locate plastic bushing (provided) and place in basin hole by pushing into hole until it snaps into place. This bushing protects the water line, wire(s),
and power cord from sharp edge of basin.  This part must be used.
7) For Single Model installations: Attach the purple wire (supplied),  on to the open terminal of the solenoid valve.
7a) For Two-Level Model installations: Attach  the purple wire (supplied), on to the open terminal of the solenoid valve to the unit that the basin hole
 was punched in for the Bottle Filling Station.  Attach the yellow wire (supplied), on to the open terminal of the solenoid valve of the other unit.
8) Reassemble Basin Assembly back on to unit. Connect the bubbler water line to the outlet side of the solenoid valve “F” (See Fig.8),  be sure to
reconnect the black wire from the solenoid valve back to the purple or yellow piggyback terminal on the solenoid valve. and the other black wire back to
the cold control or power cord (non-refrigerated unit),  fish the purple and/or yellow wire(s) up through basin hole and reattach drain to the trap.
Retighten the 4 screws two per side see Fig. 3.

STANDARD TWO-LEVEL MODELS

After completing instructions 1 thru 8 from above on the non-refrigerated side. Install filter head assembly per previous installation instructions and
reinstall basin assembly to the non-refrigerated side, re-attach wiring, bubbler  tube to solenoid valve and reinstall the two level cover plate to the left
sideof the unit.  Reinstall non-refrigerated unit to wall and reinstall drain.

TWO-LEVEL REVERSED MODELS

After completing instructions 1 thru 8 from above on the refrigerated side. Install filter head assembly per previous installation instructions and reinstall
basin assembly to the non-refrigerated side, re-attach wiring, bubbler tube to solenoid valve and reinstall the two level cover plate to the left side of the
unit. Reinstall non-refrigerated unit to wall and reinstall drain.

Fig. 5

 

Note:  Screw the locknut hand tight to seal

Fig. 6

Содержание LZWSRK -EZH2O

Страница 1: ...TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK INTOAFOUNTAIN CREATINGAN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INST...

Страница 2: ... supply pressure will ever exceed 100 psi install a pressure regulator to limit the inlet pressure to the filter to 100 psi or below DO NOT ATTACH HOT WATER LINE TO FILTER To make connections on the filter head loosen locknut Push the tube end past both o rings to a positive stop in the filter head recess approx 1 locknut may have to be backed out a little more Screw the locknut hand tight to seal...

Страница 3: ...to the open terminal of the solenoid valve to the unit that the basin hole was punched in for the Bottle Filling Station Attach the yellow wire supplied on to the open terminal of the solenoid valve of the other unit 8 Reassemble Basin Assembly back on to unit Connect the bubbler water line to the outlet side of the solenoid valve F See Fig 8 be sure to reconnect the black wire from the solenoid v...

Страница 4: ... Tee 3 8 To 1 4 Union 3 8 Water Line from Bottle Filling Unit H H R H Refrig unit L H Non Refrig unit Filter Assembly 1 4 Union Fig 7 EZ Non Pressurized Plumbing Diagram Evaporator Bubbler Solenoid Valve Water Inlet B C A EZ Plumbing Diagram after Filter Installation Pressurization Modifications Bubbler Filter Assembly 3 8 Water Line from Bottle Filling Unit Evaporator Solenoid Valve 1 4 Tee 3 8 T...

Страница 5: ...ed tabs protuding from the wall mounting plate installed on wall See Fig 11 Make sure rubber Drain Mat is installed properly on bottom of Bottle filler See Cover Illustration 9 Once Bottle Filler is installed on wall plate tabs drain mat water line wire s and power cord are installed properly push top of Bottle Filler toward wall and line up top cover two 2 holes 10 Reinstall Top Cover on Bottle F...

Страница 6: ...NSOR 1 In order to access the programming button you must remove the top cover of the bottle filler Remove the two 2 screws with a 5 32 allen wrench holding top cover to Bottle Filler Remove top cover Do not discard mounting screws they will be needed to reinstall the top cover 2 With your finger reach inside the opening and depress the program button located behind the LCD display outside of the ...

Страница 7: ...wn in Fig 12 2 Drill a 3 16 dia hole at location B shown in Fig 12 3 Remove Filter bracket from filter assembly and reinstall as shown in Fig 13 Be sure the 3 8 water inlet is facing out 4 Install plastic bushing supplied as shown into 1 3 8 hole bushing must be used so waterlines will not be cut by sharp edges of base plate 5 Install filter assembly to bottom of cooler as shown in Fig 13 with 2 8...

Страница 8: ...8 18 x 75 PH Fitting Superseal 3 8 10 mm Fitting Superseal 1 4 6 mm Filter Assy Elbow 3 8 10mm Bracket DESCRIPCIÓN DESCRIPTION Ensamblado de la Cabeza del Filtro Tornillo 8 18 x 75 PH Accesorio Supersello 3 8 10mm Accesorio Supersello 1 4 6 mm Ensamblado del Filtro Codo 3 8 10 mm Fijador Ens de tête de filtre Vis 8 18 x 75 hp Raccord Superseal 3 8 10mm Raccord Superseal 1 4 6mm Ens filtre Coude 3 ...