background image

98557C (Rev. J - 8/14)

Page 6

EZWSMD*1A     EZWSM8*1A     EZWSM8*2A     LZWSMD*1A     LZWSM8*1A     LZWSM8*2A

BF6-BF7-BF8 PROGRAMS

SETTING THE CONTROL BOARD

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the
    unit will need to be shut down and restarted. The chiller
    (if present) does not need to be shut down and restarted.
2) The units lower panel must be open to access the power
     cord and wall outlet.
3)  Shut down the unit by unplugging the power cord from the
     wall outlet.
4)  Restart the unit by plugging the power cord back into the
     wall outlet.
5) Upon start up the bottle count display will show the
    software designation of BF6, BF7, BF8, BF9 or BF11.
6) Reference the BF6-BF7-BF8-BF9 or BF11 instructions for
    setting the control board.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button the lower panel of the
      unit must be must be opened. The programming button is
      located at the bottom right corner of the upper panel.
     This area of the unit is concealed by the lower panel.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through three messages:
     

“RST FLTR” 

– Reset Filter Status LED

    

 “RST BCNT” 

– Reset Bottle Count

    

 “RNG  SET” 

– Range Set for IR Sensor

    If the program button is not pushed again the display
    will scroll through the three messages above for
    three cycles and then default back to bottle count and
     be back in run mode.
3)  When the display changes to "RST FLTR", depress
    the button again.  The display will change to show
    "FLT=". Depress the button again and the display will
    show "FLTR=0".
4) The green LED should now be illuminated indicating

    that the visual filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds
     until the display changes then release. The display will
    change and scroll through three messages:
       

“RST FLTR” 

– Reset Filter Status LED

    

 “RST BCNT” 

– Reset Bottle Count

    

 “RNG  SET” 

– Range Set for IR Sensor

2)  If the program button is not pushed again the display
    will scroll through the two messages above for
     three cycles and then default back to bottle count
     and be back in run mode.
3)  When display shows “RNG SET” push program button
    once the display will show current value
     (can be 1 – 10) e.g. 

“RNG = 3”

.

4) Once display shows current value push the program
    button to scroll through value of 1 – 10. Select the
    desired range setting.
5) Once range is selected allow approximately 4 seconds
    to pass and then the display will go back to bottle counter
     and be in run mode.
6) Test bottle filler by placing bottle or hand in front of

    sensor to make sure water is dispensed.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds
    until the display changes then release. The display will
    change and scroll through two messages:
   

  “RST FLTR” 

– Reset Filter Status LED

     

“RST BCNT” 

– Reset Bottle Count

     

“RNG SET” 

– Range Set for IR Sensor

    If the program button is not pushed again the display
    will scroll through the two messages above for
    three cycles and then default back to bottle count
     and be back in run mode.
2)  When the display changes to "RST BCNT", depress the
    button again.  The display will change to show current
     bottle count value e.g. "00033183".
3) Depress the button again and the display will change to
    "BTLCT=0" for approximately 2 seconds and then return
     to run mode displaying 00000000.
4) You can test the bottle counter by running water
    approximately 5 seconds to see bottle counter advance 1.

Содержание LZWSM8K

Страница 1: ...WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUS...

Страница 2: ...98557C Rev J 8 14 Page 2 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A FIG 3 LZWSM8 LZWSMD EZWSM8 EZWSMD ROUGH IN...

Страница 3: ...Page 3 98557C Rev J 8 14 EZWSMD 1A EZWSM8 1A EZWSM8 2A LZWSMD 1A LZWSM8 1A LZWSM8 2A LZWSM8P LZWSMDP EZWSM8P EZWSMDP ROUGH IN FIG 4...

Страница 4: ...er supply valve and union not provided Turn on the water supply and flush the line thoroughly 4b Make water supply connections for Non Fltered units Install a shut off valve and union connection to bu...

Страница 5: ...Bottle Filler the LCD Bottle Counter should illuminate 15 Verify proper dispensing by placing cup hand or any opaque object in front of sensor area and verify water dispenses Note the first initial d...

Страница 6: ...green LED should now be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display c...

Страница 7: ...play will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button...

Страница 8: ...ed allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is...

Страница 9: ...fault back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit...

Страница 10: ...ea Fig 8 LISTE DES PI CES DU FILTRE Voir Fig 8 1 2 3 4 5 6 7 WATER FILTER EXPLODED VIEW FIG 8 PRINTED IN U S A IMPRESO EN LOS E E U U IMPRIM AUX U FORPARTS CONTACTYOURLOCALDISTRIBUTORORCALL1 800 834 4...

Отзывы: