Page 5
98557C (Rev. J - 8/14)
EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
10. Lock the door in place using two set screws (provided) on the side of the panel, and a ¼ x 20 bolt through the front of
the panel into the nut in the frame.
11.
(Filtered units only) Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by
firmly inserting into head and rotating filter clockwise.
12. Turn water supply on and inspect for leaks. Fix all leaks before continuing.
13. Once unit has been inspected for leaks, and any leaks found corrected, plug Bottle Filler into wall (power cord not
supplied on 220V models). Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position.
14a. (Filtered units) Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status
along with the LCD Bottle Counter.
14b.(Non Filtered units) Once power is applied to Bottle Filler, the LCD Bottle Counter should illuminate.
15. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses.
Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is
purged from the line. A steady stream of water assures all air is removed. The sensor has a 30 second maximum
ON
time.
It may be necessary to step away from beam a few times to allow chiller tank to refill. Check for leaks.
16. Mount the lower panel to the mounting frame, aligning holes in the hinge brackets with holes in the mounting frame (three
places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the side of
the panel align with the slots on the mounting frame. If adjustments need to be made, open the door and loosen the three
screws on the hinge and adjust accordingly and then retighten the screws.
17. Lock the lower door in place using two set screws (provided) on the side of the panel.
MOUNTING FRAME
CHILLER
FILTER LOCATION
(OPTIONAL)
HINGE BRACKETS
DRAIN LOCATION
UPPER PANEL
LOWER PANEL
FIG. 7