CARTRIDGE REPLACEMENT

Loosen cartridge nut (1) by turning it 
counter-clockwise and lift out the cartridge (2). Insert 
new cartridge. Reinstall the handle.

Shut off water supply. With valves in "closed" position, 
Loosen the set screw (1). Remove handle (2) from 
valve stem (3). Loosen the screw (4) from valve stem 
(3) and unscrew the cap (5) from the cartridge nut (6).

3

6

5

4

1

2

1

2

FLOW REGULATOR REPLACEMENT

2

1

2

1

1

This faucet ships with a 1.5 GPM flow restrictor installed.  
An optional 2.2 GPM flow restrictor is also included in the 
box.

To switch the flow rate of the faucet:

1. Disassemble the quick connect assembly by 

separating the connector (1) and quick connect (2).
2. Replace 1.5 GPM connector (green) with the 2.2 GPM 
connector.
3. Reinstall the quick connect assembly.

Congratulations on your purchase of an Elkay product. 

Although your product is extremely durable, attention should 

be given to the care, cleaning and maintenance of this  
product.  Cleaning agents and abrasives may cause damage, 

which may result in oxidation and discoloration.

By following these simple guidelines for proper care and 
cleaning, it will give you years of enjoyment:

TO CLEAN: Simply wipe gently with a damp cloth and blot dry 
with a soft towel. A common rule of thumb is: when you dry off, 
dry off your product.

·

 Avoid build-up of soap, toothpaste or mineral deposits, as 

     these tend to have an adverse effect on the appearance of     
     the product.    

·

 NEVER use cleaning products of any kind on this product -   

     especially those containing ammonia, bleach or alcohol - or  
     those with any form of abrasive.      

 

CARE AND CLEANING INSTRUCTIONS

FOR CARE AND MAINTENANCE:

·

The water in certain areas of the world can be very caustic -   

    standing water around the product can cause damage. Be    
    sure to remove standing water with a dry, soft cloth as soon  
    as possible.    

·

For polished brass finishes, as often as once a week, you 

    can apply a paste wax or special, non-abrasive, brass
    coating (DO NOT APPLY POLISH).   

·

Before applying a protective coating, gently brush the entire 

    fixture using a soft tooth brush. This will remove any dirt or 
    deposit build-up.   

·

These simple steps will add temporary protective coating to   

     your faucet and extend the life of the finish.

     Failure to follow care and cleaning will void your warranty. 
     For additional information, please visit elkayusa.com

.

Содержание LK2500

Страница 1: ...0 INSTALLATION OWNER S MANUAL OPTIONAL 2 2GPM FLOW REGULATOR You choose the flow rate This faucet ships with an eco friendly 1 5GPM flow regulator installed If you desire higher flow rate a 2 2GPM flow regulator has also been included in the box Switching the flow regulator is simple See the Flow Regulator Replacement section for details Important ...

Страница 2: ...ead nut 3 onto mounting shank Do not overtighten Before installation screw bolts to the large escutcheon Insert escutcheon assembly through the gasket and the holes of the sink Shut off water supplies Before installation remove quick connect assembly 1 from the free end of hose If installing the faucet with the escutcheon begin with step 2A If installing the faucet with flange begin with step 3 ST...

Страница 3: ...ng it from the hose counterclockwise Turn the faucet on to the warm position where it mixes hot and cold water Flush water lines for one minute Check for leaks Re tighten any connections if necessary but do not overtighten Reinstall spray head by hand tightening it back onto the hose WARNING Please carefully read and properly follow the instructions for installation found in this manual Make conne...

Страница 4: ...se simple guidelines for proper care and cleaning it will give you years of enjoyment TO CLEAN Simply wipe gently with a damp cloth and blot dry with a soft towel A common rule of thumb is when you dry off dry off your product Avoid build up of soap toothpaste or mineral deposits as these tend to have an adverse effect on the appearance of the product NEVER use cleaning products of any kind on thi...

Страница 5: ...nstallation and any damages to other property 5 All industrial commercial and business use whose purchasers are hereby extended a limited lifetime on mechanical parts and 5 years on finish ELKAY LIMITED LIFETIME WARRANTY What you must do to obtain warranty service Either write to Elkay attention Customer Care 2222 Camden Court Oak Brook IL 60523 or call 1 800 223 5529 Please provide date of purcha...

Отзывы: