Page 5

1000002684  (Rev. B - 09/18)

EZS8WS_2G, LZS8WS_2G, LZSDWS_2G

Operation: Bottle Filler Control Board Set-Up BF11-BF12

VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall 

    outlet. 

4)  Restart the unit by plugging the power cord back into the wall 

    outlet.

5) Upon start up, the bottle count display will show the software 

    designation of BF11 or BF12.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button, remove the top cover of the bottle- 

  filler. Remove the two (2) screws holding top cover to bottle-filler 

  with a 5/32” allen wrench. Remove top cover. Do not discard

  mounting screws, they will be needed to reinstall the top cove after  

  programming operations are completed. The programming button  

  is located at the top right side of the unit on the control board.  

 

NOTE: When applicable, there is also an alternate reset button  

  located on the lower part of the water cooler. After removing

  the bottom cover, the reset button will be located on the left 

  side of the cooler, mounted on the side panel support.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting, 

  "1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll 

    through two messages:

       

“RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  

When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

     

  “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  

When display shows “UNIT TYPE” push program button once the

    display will show current value.  

Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is  

  selected the display 

    will show the new value.  

(Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     

“NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate 

  1 bottle equal to 20 oz.

5)  

Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      

“RST FLTR” – Reset Filter Status LED

      

“SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

     

 “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  

When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5)  Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for approximately 

  9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      

“RST FLTR” – Reset Filter Status LED

      

“SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  

When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

Содержание EZS8WSVRL2K

Страница 1: ...fter installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow ele...

Страница 2: ...1 4 Remove the four 4 screws holding the lower front panel at the bottom of cooler Remove the front panel by pulling straight down and set aside Installation Water Line connection 1 Ensure Mains Water Supply has Water Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm unplated copper tube to Water Shut off Valve Other end of tube should be connected to inlet...

Страница 3: ...e and yellow wires from coolers to the purple and yellow wires on the back of the unit purple to purple yellow to yellow Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket remove this insulation from the 3 8 tube but do not discard Feed the waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth...

Страница 4: ...t plug end of International Cord Sets from the Cooler and Bottle Filler into electrical outlet Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 12 13 14 16 15 18 17 21 20 19 Once power is applied to Bottle Filler the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter Verify proper dispensing by placing cup ha...

Страница 5: ... the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST ...

Страница 6: ...nly be cleaned with mild soap and water or Windex glass cleaner and a clean soft cloth Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty 2 Bubbler Mineral deposits on the orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 3 mm diameter or small diameter wire CAUTION DO NOT f...

Страница 7: ... quick connect fitting see above When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten After servicing replace the lower front panel and four 4 screws 3 Switches Behind the Push Bar The regulator in an EZ cooler is always held fully open by the use of a single regulator nut Water is not dispensed until the pushbar is depressed to ac...

Страница 8: ... 36299C 1000004564 1000001812 36004C 97446C 36300C 27416C 27413C See Filter Table 36066C 36067C 28030C 35826C Description Hanger Bracket Basin Stainless Steel Wiring Front Side Push Bar Compr Service Pak 230V 50Hz Polytube Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ BF Brckt Tube Ftg Clamp In Line Strainer Kit Solenoid Valve Regulator Assy Kit Flexi Bubbler O Rin...

Отзывы: