background image

Page 4

1000002684  (Rev. B - 09/18)

EZS8WS_2G, LZS8WS_2G, LZSDWS_2G

With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the 

three (3) angled tabs protruding from the wall mounting plate, installed on wall (See Fig. 6). Make sure 

round boss in gasket fits in hole of basin. 

Once Bottle Filler is installed on wall plate tabs, water line, wire(s) and power cord are installed properly, 

push top of Bottle Filler toward wall and line up top cover two (2) holes.

Reinstall Top Cover on Bottle Filler (See Fig. 3) with two mounting screws from step 1 above. Caution: do 

not over tighten screws.

Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of 

the water cooler by connecting the 3/8” water line to the tee.

Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly 

inserting into head and rotating filter clockwise. NOTE: If existing plumbing rough in locations (Drain, 

Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet, the filter can 

be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.

Turn water supply on and inspect for leaks. Fix all leaks before continuing.

Once unit has been inspected for leaks and any leaks found corrected, connect plug end of International 

Cord Sets from the Cooler and Bottle Filler into electrical outlet. Be sure to reinstall fuse to the circuit or 

switch the circuit breaker back to the “ON” position.

12.

13.

14.

16.

15.

18.

17.

21.

20.

19.Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle 

Counter.

Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first 

initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.

Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.

Operation: Start-Up

Turn on the building water supply and check all connections for leaks.

Ensure unit is plugged into electrical supply. Unit must have electrical power to have water flow.

WARNING:  

Exposed electrically energized components.  Use extreme caution.

Purge air from all water lines by: 

  •   Depressing button or front push bar of cooler/fountain. 

  •   Placing cup, hand, or any opaque object in front of Bottle Filler sensor area to dispense water. 

  •   NOTE: Steady stream of water assures all air is removed. 

Recheck all water and drain connections with water flowing through system.

Replace the lower front panel ensuring that the top metal edges are secured inside of the upper shroud. Replace all four (4) screws previously 

removed.

5.

4.

2.

3.

1.

Figure 6

BOTTLE FILLING UNIT

WALL MOUNTING PLATE

11

Basin

Locknut

Flexi-Guard Bubbler Assy

Vandal Resistant Bubbler Assy

Basin

28

Содержание EZS8WSVRL2K

Страница 1: ...fter installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules This is to allow ele...

Страница 2: ...1 4 Remove the four 4 screws holding the lower front panel at the bottom of cooler Remove the front panel by pulling straight down and set aside Installation Water Line connection 1 Ensure Mains Water Supply has Water Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm unplated copper tube to Water Shut off Valve Other end of tube should be connected to inlet...

Страница 3: ...e and yellow wires from coolers to the purple and yellow wires on the back of the unit purple to purple yellow to yellow Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket remove this insulation from the 3 8 tube but do not discard Feed the waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth...

Страница 4: ...t plug end of International Cord Sets from the Cooler and Bottle Filler into electrical outlet Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 12 13 14 16 15 18 17 21 20 19 Once power is applied to Bottle Filler the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter Verify proper dispensing by placing cup ha...

Страница 5: ... the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST ...

Страница 6: ...nly be cleaned with mild soap and water or Windex glass cleaner and a clean soft cloth Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty 2 Bubbler Mineral deposits on the orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from the orifice with a small round file not over 1 8 3 mm diameter or small diameter wire CAUTION DO NOT f...

Страница 7: ... quick connect fitting see above When installing replacement bubbler and pedestal tighten locknut only to hold parts snug in position Do Not Overtighten After servicing replace the lower front panel and four 4 screws 3 Switches Behind the Push Bar The regulator in an EZ cooler is always held fully open by the use of a single regulator nut Water is not dispensed until the pushbar is depressed to ac...

Страница 8: ... 36299C 1000004564 1000001812 36004C 97446C 36300C 27416C 27413C See Filter Table 36066C 36067C 28030C 35826C Description Hanger Bracket Basin Stainless Steel Wiring Front Side Push Bar Compr Service Pak 230V 50Hz Polytube Cut To Length Assy Shroud Upper Front Side Push Drier Kit Drain Replacement EZ BF Brckt Tube Ftg Clamp In Line Strainer Kit Solenoid Valve Regulator Assy Kit Flexi Bubbler O Rin...