With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the
three (3) angled tabs protruding from the wall mounting plate, installed on wall (See Fig. 6). Make sure
round boss in gasket fits in hole of basin.
Once Bottle Filler is installed on wall plate tabs, water line, wire(s) and power cord are installed properly,
push top of Bottle Filler toward wall and line up top cover two (2) holes.
Reinstall Top Cover on Bottle Filler (See Fig. 3) with two mounting screws from step 1 above. Caution: do
not over tighten screws.
Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of
the water cooler by connecting the 3/8” water line to the tee.
Install filter cartridge, remove filter from carton, remove protective cap, attach filter to filter head by firmly
inserting into head and rotating filter clockwise. NOTE: If existing plumbing rough in locations (Drain,
Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet, the filter can
be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.
Turn water supply on and inspect for leaks. Fix all leaks before continuing.
Once unit has been inspected for leaks and any leaks found corrected, connect plug end of International
Cord Sets from the Cooler and Bottle Filler into electrical outlet. Be sure to reinstall fuse to the circuit or
switch the circuit breaker back to the “ON” position.
12.
13.
14.
16.
15.
18.
17.
21.
20.
19.Once power is applied to Bottle Filler, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle
Counter.
Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first
initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.
Operation: Start-Up
Turn on the building water supply and check all connections for leaks.
Ensure unit is plugged into electrical supply. Unit must have electrical power to have water flow.
WARNING:
Exposed electrically energized components. Use extreme caution.
Purge air from all water lines by:
• Depressing button or front push bar of cooler/fountain.
• Placing cup, hand, or any opaque object in front of Bottle Filler sensor area to dispense water.
• NOTE: Steady stream of water assures all air is removed.
Recheck all water and drain connections with water flowing through system.
Replace the lower front panel ensuring that the top metal edges are secured inside of the upper shroud. Replace all four (4) screws previously
removed.
5.
4.
2.
3.
1.
Figure 6
BOTTLE FILLING UNIT
WALL MOUNTING PLATE
11
Basin
Locknut
Flexi-Guard Bubbler Assy
Vandal Resistant Bubbler Assy
Basin
28