background image

PAGE 4

98115C (12/04)

EFOA8*1J

56082C
61313C
40045C
50986C
27316C
56073C
40322C

56011C

55997C
75580C
31513C
35890C
66743C
56237C
31490C
30664C
20282C
70018C
66703C
36094C
36158C
50368C
35959C
55996C
45702C
66576C
66534C
27278C
36028C
35891C
27279C
75568C
56092C
27961C
35768C

REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

PRINTED IN U.S.A.

PARTS LIST 115V

ITEM NO.

PART NO.

DESCRIPTION

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19

20*

21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

RIGHT

PANEL

FRONT

PANEL

LEFT

PANEL

COLOR

TABLE

Gray Beige
Almond
Stainless Steel
Sandalwood
Granite
Light Gray

20622C
21460C
20624C
21458C
27165C
27166C

20623C
21461C
20625C
21459C
27168C
27169C

27272C
27273C
27270C
27274C
27271C
27275C

Regulator Retaining Nut
Regulator
Hex Nut
Regulator Holder
Basin
Bubbler Assembly
Orifice Assembly
Housing Assembly
Pedestal
Bubbler Locknut
Cold Control
Power Cord
Condenser
Fan Shroud
Fan Motor
Fan Blade
Fan Bracket
Fan Blade Nut
Drier
Compressor Serv. Pak
Overload
Receptor-Drain
Relay
Strainer
Tailpipe Assy
Heat Exchanger
Evaporator
Regulator Bracket
Sensor (clear)
Solenoid Valve Assembly
Cross Brace
Screw-Evaporator Mtg
Poly Tubing (Cut To Length)
Brkt-Strain Relief
Relay Cover

*INCLUDES RELAY & OVERLOAD.  IF UNDER WARRANTY,
REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE:  All correspondence pertaining to any of the above water coolers
or orders for repair parts MUST include Model No. and Serial No. of cooler,
name and part number of replacement part.

Содержание EFOA Series

Страница 1: ...PAGE 1 98115C 12 04 EFOA8 1J FIG 1 5 25 14 12 SEE FIG 4 24 28 26 20 21 23 35 15 16 17 18 19 32 11 27 30 31 29 22 33 34 EFOA Pressure Cooler USES HFC 134A REFRIGERANT INSTALLATION CARE USE MANUAL 13 ...

Страница 2: ...A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS EMPLACEMENT RECOMMANDÉ D ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3 8 PO 9 5 mm D E CONNECTANT U...

Страница 3: ...nt screw clockwise to increase range and counterclockwise to decrease range See Fig 3 CAUTION Complete range of sensor 24 46 inches 610 1168mm is only one turn of the adjusting screw C Replace front panel SENSOR CONTROL If sensor fails to operate valve mechanism or operates erratically check the following A Ensure there are no obstructions within a 40 inch 1016mm radius in front of cooler B Check ...

Страница 4: ...andalwood Granite Light Gray 20622C 21460C 20624C 21458C 27165C 27166C 20623C 21461C 20625C 21459C 27168C 27169C 27272C 27273C 27270C 27274C 27271C 27275C Regulator Retaining Nut Regulator Hex Nut Regulator Holder Basin Bubbler Assembly Orifice Assembly Housing Assembly Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compres...