NOTE:
WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN
NUT (ITEM 10) ONLY TO HOLD PARTS
SNUG IN POSITION.
DO NOT OVER TIGHTEN.

FIG. 4

BASIN

7

8

9

10

6

WIRING DIAGRAM

This Drawing is merely for illustrating the

components of the electrical sytem.

SENSOR RANGE ADJUSTMENT

:  The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36

     inches (914 mm).  If actual range varies greatly from this or a different setting is desired, follow the range adjustment
     procedure below:
A.  Remove front panel of cooler.
B.  Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to
     decrease range (See Fig. 3).

     CAUTION

:  Complete range of sensor (24-46 inches/610-1168mm) is only one turn of the adjusting screw.

C.  Replace front panel.

SENSOR CONTROL

:  If sensor fails to operate valve mechanism or operates erratically, check the following.

A.  Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.
B.  Check wire connections at the solenoid valve and sensor.  

CAUTION

:  Make sure unit is unplugged before checking any

     wiring.
C.  Ensure proper operation of solenoid valve.  If there is an audible clicking sound yet no water flows, look for an obstruction
     in the valve itself or elsewhere in the water supply line.

RANGE ADJUSTMENT SCREW

28

4

29

30

2

3

1

TO PRECOOLER

31

TO SOLENOID VALVE (ITEM 32)

FIG. 3

TO EVAP. ASSY.(ITEM 29)

Содержание EFOA Series

Страница 1: ...PAGE 1 98115C 12 04 EFOA8 1J FIG 1 5 25 14 12 SEE FIG 4 24 28 26 20 21 23 35 15 16 17 18 19 32 11 27 30 31 29 22 33 34 EFOA Pressure Cooler USES HFC 134A REFRIGERANT INSTALLATION CARE USE MANUAL 13 ...

Страница 2: ...A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS EMPLACEMENT RECOMMANDÉ D ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3 8 PO 9 5 mm D E CONNECTANT U...

Страница 3: ...nt screw clockwise to increase range and counterclockwise to decrease range See Fig 3 CAUTION Complete range of sensor 24 46 inches 610 1168mm is only one turn of the adjusting screw C Replace front panel SENSOR CONTROL If sensor fails to operate valve mechanism or operates erratically check the following A Ensure there are no obstructions within a 40 inch 1016mm radius in front of cooler B Check ...

Страница 4: ...andalwood Granite Light Gray 20622C 21460C 20624C 21458C 27165C 27166C 20623C 21461C 20625C 21459C 27168C 27169C 27272C 27273C 27270C 27274C 27271C 27275C Regulator Retaining Nut Regulator Hex Nut Regulator Holder Basin Bubbler Assembly Orifice Assembly Housing Assembly Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compres...

Отзывы: