background image

97565C (Rev. J - 8/07)

EDFP210FP*B     EDFP214FP*B     EDFP217FP*B

PAGE 3

FIG

. 2

FINISHED FLOOR

1. Wall should already be framed for the fountain using dimensions shown in Fig. 1.

 Shown dimensions pertain to installation location.

   

These dimensions are required for compliance with 

ANSI S

tandard 

A1

17.1. and 

ADA

 (Framing shown for reference only).

2. Remove bottom cover from fountain and save the screws.

3. Inst

all the fount

ain 

using bolt

s and washers (not provided). 

T

ighten securely

.

4. Attach drain tube

 to fountain and cut to required length using the freeze resistant box as a guide.

5. Install freeze-resistant box 

- see box instructions.

6. Replace 

bottom cover

.

EDFP210FP/EDFP214FP

ROUGH-IN DRA

WINGS

Содержание EDFP210FPC

Страница 1: ...ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON EDFP210FPC EDFP217FPC To as...

Страница 2: ...IG 1 PAGE 2 LEGEND A MOUNTING BOLT LOCATIONS 4 3 8 DIA NOT PROVIDED B 7 8 DIA 22mm HOLE FOR WATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D 1 3 4 44mm HOLE FOR WASTE LINE FINISHED FLOOR ED...

Страница 3: ...quired for compliance with ANSI Standard A117 1 and ADA Framing shown for reference only 2 Remove bottom cover from fountain and save the screws 3 Install the fountain using bolts and washers not prov...

Страница 4: ...IG 3 LEGEND A 3 8 DIA 10mm SLOTS FOR MOUNTING UPPER HANGER BRACKET B 7 8 DIA 22mm HOLE FOR WATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D MOUNTING BOLT LOCATIONS 8 3 8 DIA NOT PROVIDED E...

Страница 5: ...ANSI Standard A117 1 and ADA Framing shown for reference only 2 Remove bottom covers from fountains and save the screws 3 Install the fountains using bolts and washers not provided Tighten securely 4...

Страница 6: ...97565C Rev J 8 07 EDFP210FP B EDFP214FP B EDFP217FP B PAGE 6 FIG 8 FIG 9 FIG 5 FIG 6 See Fig 9 See Fig 5 FIG 7 CABLE SHEATHADJUSTMENT To Increase Free Play To Reduce Free Play...

Страница 7: ...ve stop To remove tubing from the fittings relieve water pressure push in on dark gray collar while pulling out on the tubing See Figure 11 5 Connect drain and water supply lines to the freeze resista...

Страница 8: ...NAPBUSHING BUMPER REG VALVEASSY PUSHBUTTON EXTENSION PIVOTROD FOUNTAINARM SHORT FOUNTAINARM LONG BOTTOM COVER PLATE SHORT BOTTOM COVER PLATE LONG BACK PANELASSY EDFP217FPC CAPSCREW WASTE ARM ASSY POLY...

Отзывы: