background image

97565C (Rev. J - 8/07)

EDFP210FP*B     EDFP214FP*B     EDFP217FP*B

Installation/Care/Use Manual

EDFP210FPC   EDFP214FPC   EDFP217FPC

Soft Sides

 Freeze Resistant Fountains

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

EDFP210FPC

EDFP217FPC

To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-
TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s)
contains the Freeze Resistant Package(s) 

LKFRB1

 that are installed on an interior

heated wall. The interior space must maintain a minimum temperature of 50° F (10° C).
Refer to the Freeze Resistant Package for the rough-in dimensions for installation.

Installer

EDFP214FPC

Содержание EDFP210FPC

Страница 1: ...ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON EDFP210FPC EDFP217FPC To as...

Страница 2: ...IG 1 PAGE 2 LEGEND A MOUNTING BOLT LOCATIONS 4 3 8 DIA NOT PROVIDED B 7 8 DIA 22mm HOLE FOR WATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D 1 3 4 44mm HOLE FOR WASTE LINE FINISHED FLOOR ED...

Страница 3: ...quired for compliance with ANSI Standard A117 1 and ADA Framing shown for reference only 2 Remove bottom cover from fountain and save the screws 3 Install the fountain using bolts and washers not prov...

Страница 4: ...IG 3 LEGEND A 3 8 DIA 10mm SLOTS FOR MOUNTING UPPER HANGER BRACKET B 7 8 DIA 22mm HOLE FOR WATER SUPPLY TUBE C 7 8 DIA 22mm HOLE FOR OPERATING CABLE D MOUNTING BOLT LOCATIONS 8 3 8 DIA NOT PROVIDED E...

Страница 5: ...ANSI Standard A117 1 and ADA Framing shown for reference only 2 Remove bottom covers from fountains and save the screws 3 Install the fountains using bolts and washers not provided Tighten securely 4...

Страница 6: ...97565C Rev J 8 07 EDFP210FP B EDFP214FP B EDFP217FP B PAGE 6 FIG 8 FIG 9 FIG 5 FIG 6 See Fig 9 See Fig 5 FIG 7 CABLE SHEATHADJUSTMENT To Increase Free Play To Reduce Free Play...

Страница 7: ...ve stop To remove tubing from the fittings relieve water pressure push in on dark gray collar while pulling out on the tubing See Figure 11 5 Connect drain and water supply lines to the freeze resista...

Страница 8: ...NAPBUSHING BUMPER REG VALVEASSY PUSHBUTTON EXTENSION PIVOTROD FOUNTAINARM SHORT FOUNTAINARM LONG BOTTOM COVER PLATE SHORT BOTTOM COVER PLATE LONG BACK PANELASSY EDFP217FPC CAPSCREW WASTE ARM ASSY POLY...

Отзывы: