background image

98712C (Rev. A - 3/11)

DRKR10C

Page 4

72043210

LK142

10031C

100322740560

40048C
40089C
40322C
45675C
61313C
70012C

72460042

A54800
A54888

1
2
3
4
5
6
7
8
9

10

11

12
13

PARTS LIST

ITEM NO.

PART NO.

DESCRIPTION

Basin Assembly
Bubbler Assembly
Regulator Nut
Gasket
Button Cap
Nut Cover Cap
Orifice Assembly
Bubbler Body
Regulator Assembly
Lock Nut
Metal Washer
Nipple
Screen

PRINTED IN U.S.A.

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

TROUBLESHOOTING & MAINTENANCE

Orifice Assembly: Mineral deposits on orifice can

cause water flow to spurt or not regulate. Mineral deposits
may be removed from the orifice by poking with a small round
file not over 1/8” diameter, or using a small diameter wire.

!

CAUTION:

DO NOT file or cut orifice
material.

Stream Regulator: If orifice is clean, regulate flow as in

Step 10, Page 2 of the installation instructions. If replacement
is necessary, see parts list for correct regulator part number.

Basin

Figure 6

12

6

5

3

8

4

13

11

9

7

10

2

Отзывы: