background image

The 

Ceiling Mount PIR Timer (3 wire) 

is part of the Elkay family of switches, 

timers and detectors which save 

energy and increase convenience in 

and around your home, garden  

or premises.

Rating at 240V ac 50Hz

•  

All load types 10A

•  

Time Delay: 2min - 1 hour

•  

Sensitivity adjustment

 / 

Test mode

•  

Auto and manual Lux Sensor for  

   daylight control

•  

Surface and flush mounted options

•  

Interchangeable white / chrome fascias

Usage

The PIR sensor has been designed to switch 
lighting, heating and ventilation loads up
to 10A. The unit is switched on by the 
detection of moving infra red heat within
a specified range. When infra red heat, such 
as a moving body, is no longer detected,
the unit will switch off the load after the 
adjustable time period has elapsed.
If infra red heat is detected again during the 
timing period, the timing sequence will
restart. The unit has a lux level adjustment 
and Auto Lux function, which measures
the ambient light levels and prevents lighting 

being switched on, when there is sufficient 
lighting in the room. There is sensitivity 
adjustment and test mode function added 
for your convenience.

IMPORTANT

 

a power factor correction 

capacitor of 4 microfarads may be 
required when switching low wattage 
loads, e.g. LED loads. the capacitor is fitted 
across switch live and neutral supplies of 
suitable Elkay capacitors can be found at 
your stockist (ref. pfcc-1). Do not insulation 
resistance test this product. Remove before 
testing or test circuit prior to fitting.

 –

CEILING MOUNT

PIR TIMER

 

374B-1

    

3 wire

Instruction Guide

BROOK DESIGN HARDWARE LTD

B

D

H

B

D

H

BROOK DESIGN 

HARDWARE LTD

B

D

H

BROOK DESIGN 

HARDWARE LTD

BDH

BROOK DESIGN 

HARDWARE LTD

B

D

H

Содержание 374B-1

Страница 1: ...ff the load after the adjustable time period has elapsed If infra red heat is detected again during the timing period the timing sequence will restart The unit has a lux level adjustment and Auto Lux function which measures the ambient light levels and prevents lighting being switched on when there is sufficient lighting in the room There is sensitivity adjustment and test mode function added for ...

Страница 2: ...osition of the dip switch Dip switch 4 is only used for Setting Automatic 150 Lux or Manual Lux ONLY Diagram 2 Diagram 2 heating and ventilation They should not be placed within 1 metre of the load Sensors work when objects move across their field of view Position the sensor where people will be detected walking across the zones rather than towards the zones identified in Diagram 1 Adjust sensitiv...

Страница 3: ...tical position and insert unit into the hole Release unit ensuring arms are securely in place For surface mounting fit surface mount cup onto ceiling or conduit terminal box and return connected PIR into surface mount cup Step 4 Remove the fascia by turning anti clockwise to show the lux pot sensitivity pot and the timing lux Dip switches Please adjust the Lux Level and Sensitivity potentiometer g...

Страница 4: ...ximately 1 minute to initialise and will flash rapidly after the mains power is first applied to allow the sensor to learn its environment The load will be ON after 7 seconds initially then switch off after 1 minute if there is no detection in the zones Operation of the Unit In standard operation the PIR will now sense infra red heat when a person or source of heat passes through the detection zon...

Отзывы: