09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 14
EST 204, EST 404, EST 804
16.
Learn mode MO 43
The controller must learn the following parameter during the installation:
- Running time for opening and closing (Gate must be completely open when starting procedure)
In addition you may alter the default values of the following parameter:
- Position for partial opening (BTG)
- Pause time for automatic closure
16.1.
Learning the running time
a) Disengage the opener and open the gate as far as it should open when operating but not against the
stopper „gate open“.
b) With the opener engaged, press the learn button for approx. 3 seconds until the diagnostic LED starts
flashing.
c) Push the learn button. The opener will close slowly and switch off when it is completely closed. If the
learn button is held down the opener will close quickly.
d) The LED now flashes in one second intervals. If automatic closure is to be used press the learn button
after the required time to stay open, otherwise press the learn button straight away.
e) This time only takes effect when automatic closure is activated (operating mode switch 3 ‘on’).
f) Setup is complete, the LED turns off.
16.2.
Setup for the partial opening module
The standard setup must be completed. The pedestrian opening is automatically set to half of the total
distance which the gate opens. You may select any other position as partial open.
a) With the opener engaged, press the learn button for approx. 3 seconds until the diagnostic LED starts
flashing.
b) Open the gate with the service button (BT) as far as it’s intended to open for e.g. pedestrians.
c) Push the partial opening button (BTG) - the gate closes slowly and switches off at the end stopper.
d) The LED flashes in one second intervals.
e) Press the learn button when the time to stay open for partial opening has elapsed. This time is only
effective when automatic closure for partial opening is activated (operating mode switch 2).
f) Setup for partial opening is complete - the LED turns off.
g) Make a test run and set the power trimmers so that they give a little more power than the opener
requires.
17. Operation after power supply break
The gate closes quickly after the first signal and switches off at the end stopper. The re-orientation is
complete.
If safety devices are activated the gate stops. When the safety devices are free again, the gate closes
quickly on the first signal.
If the gate is closed, then it will only open after the second signal.
The normal operating cycle is in effect.