09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 13
EST 204, EST 404, EST 804
14.2.
Output terminals MO 43
Terminal Function
18 Vac
Power supply for photocells.
Warning light
The light is always on when the opener runs, or if a pre-warning time is active.
(230 V, max. 100 W)
Motor +
Motor -
Motor connector, for motor types: 1x 404.258, 2x 404.258, 1x 404.259, 2x 404.259, 1x
404.458
14.3.
Indication lights on the MO 43
LED name
Colour
Function
LS
green
On, when all photocell contact (LS) are closed.
BTG
green
On, when contact BTG is closed.
BT
green
On, when contact BT is closed.
BA
green
On, when contact BA is closed.
BZ
green
On, when contact BZ is closed.
BS
green
On, when contact BS is closed.
DW
red
On, when DW safety edge is pressed.
Vp
yellow
On, when power supply is present.
Diag/Funk yellow Diagnosis
display
and display for radio receiver.
15.
Operating modes MO43 (DIP switches)
The settings are made with the dip-switches 1 to 6.
a) Switch 1 on:
Interrupting the photo-cell stops the gate, when the photo-cell is free the gate opens.
Switch 1 off:
Interrupting the photo-cell stops the gate during the closing phase, it then re-opens
immediately. During opening the photo-cell has no effect.
b) Switch 2 on:
The gate closes automatically from the partial open position when the registered time to
remain open and a pre-warning time (if activated) have elapsed.
Switch 2 off:
No automatic closure from the partial open position.
c) Switch 3 on:
The gate closes automatically from the open position when the registered time to
remain open and a pre-warning time (if activated) have elapsed.
Switch 3 off:
No automatic closure from the open position.
d) Switch 4 on:
A pre-warning of four seconds before the gate closes, this also applies to closing from
the pedestrian position.
Switch 4 off:
No pre-warning before gate closes.
e) Switch 5 on:
A pre-warning of four seconds before the gate opens, this also applies to opening for
pedestrians.
Switch 5 off:
No pre-warning before gate opens.
f) Switch 6 on:
The buttons for opening (BA) and closing (BZ) are dead man’s buttons (The gate only
moves if one of them is pressed). Radio remote control does not work in this mode.
Safety equipment and the limits of movement are still effective.
Switch 6 off:
The control box works with locking relays.