background image

KNX Metering gateway

Art. No. : 135 16 140

Operating instructions

1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. During installation and cable routing, comply with the
regulations and standards which apply for SELV circuits.

Fire hazard. Only use limited-capacity power sources according to EN 60950-1. Observe
the technical data.

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1

(1) Connection for M-bus devices
(2) Connection for wM-bus antenna
(3) Ethernet connection
(4) D0 connection for optical communication head
(5) Slot for micro SD card
(6) For future expansions; has no function
(7) Two S0 connections
(8) Power supply connection
(9) KNX connection
(10) Status LEDs

KNX Metering gateway

1/9

82594604

05.02.2016

Содержание 135 16 140

Страница 1: ...ply for SELV circuits Fire hazard Only use limited capacity power sources according to EN 60950 1 Observe the technical data These instructions are an integral part of the product and must remain with...

Страница 2: ...ction and commissioning of M bus and wireless M bus devices is a prerequisite to complete understanding of these instructions Intended use Transmission of measurement values from metering systems with...

Страница 3: ...2 seconds Impulse recognized SD Card Red Writing on micro SD card is not possible Red flashing Micro SD card full Yellow flashing Reading micro SD card Green blinking Writing on micro SD card Insert m...

Страница 4: ...point gateways as centrally as possible and guide cables along the supply cables As needed use surge protection with coarse medium and fine protection Figure 3 Avoid looping with other circuits or com...

Страница 5: ...a mobile device can be connected either directly via a network distributor or via a router Figure 5 Connection example for PC or router Use network cables with RJ45 connectors o Connect Ethernet cabl...

Страница 6: ...ity depends on the distance from the measurement point as well as the transmission field strength of the measuring point To ensure good transmission quality keep a sufficient distance from possible in...

Страница 7: ...cation head on the measurement point optical interface o Relive strain on cable i To prevent manipulation of communication head e g pulling from measurement point by unauthorized persons access to the...

Страница 8: ...to the directive 2014 53 EU The complete text of the EU Declaration of Conformity is available under the Internet address www elka de compliance Legal Notice This product incorporates open source sof...

Страница 9: ...No 110 01 212 6 3 Warranty We reserve the right to make technical and formal changes to the product as long as they are the result of technical progress Our products are under warranty within the scop...

Отзывы: