KEYPAD INTERNAL TEMPERATURE SENSOR

Every standard ELK-M1KP has a built-in temperature sensor, which detects the surrounding ambient temperature.  The sensor
temperature may be displayed on the LCD, and read from another keypad or the telephone remote control.  It may also be used with
the Elk-RP Whenever/And/Then Rules to automatically cause an action or control something.  i.e., a fan, pump, light, etc.

Viewing a Keypad temperature sensor reading

1. To view a keypad temperature sensor press the ELK key once (enter code if prompted), then press the RIGHT arrow to select the

View/Control Automation menu.

2. Press the 5 key (or scroll up) to display: 4-Keypad Temperature, then press the RIGHT arrow key.
3. The first Keypad (Keypad 01 will be displayed along with its Name, Keypad Number, and Temperature.
4. Additional Keypad Temperature sensors (if any) may be displayed by entering the 2 digit Keypad number OR by scrolling with the

UP or DOWN arrow keys.  To exit from this menu press the * key.

Using a Keypad temperature reading in a Rule to create an action or output

The following is an example of an ELK-RP Whenever/And/Then Rule to automatically turn on Output 3 (controlling a Fan, etc.) for 10
minutes whenever the Keypad temperature reading exceeds 90 degrees.
1. Start RP and open an account.  Click the Automation tab and the Rules tab followed by New.
2. Click Trigger, then point to Time Occurrence, then Every X Seconds, and then click to select.  **
3. In the block beside the words Fixed Value, type in 30 and click OK.
4. Click And, follwed by Temperature which is located near the bottom of the drop down list.
5. Highlight the Keypad temperature sensor (by name), click the Greater than button, and change the temperature selection number

to 90.  Make sure the button beside F is selected, and click OK.

6. Click Then, followed by Turn Output On/Off.  Highlight Output 3 (use the scroll down arrow), make sure the button beside Turn on

is selected, then select the box labeled For.  Highlight the hrs:mins:secs  window and enter 00:10:00 (10 minutes).  Click OK.
Double check everything and click Done.

7. The completed Rule should resemble the example below.

**  

Numerous triggers may be used for a temperature type rule, i.e., time occurence, arming of the security system, opening of a zone, etc.  However,

the M1 does not allow a temperature reading to be used as a trigger.  This helps prevent a false activation "runaway" that could occur simple because
the temperature has fluctuated by a degree or fraction of a degree.  Instead, the AND command is used to compare or "test" a temperature sensor
reading against a target value, each time the trigger occurs.  The target value is programmable and the compare options are "Equal to, Not equal to,
Less than, and Greater than".  The "Equal to" is not recommended as a compare opton because it may be impossible for a temperature reading to be
exactly at the target value when the trigger occurs.

TEMPERATURE READING ADJUSTMENT   

If the Keypad internal temperature sensor appears to read higher or lower than other room

thermostats/thermometers, it may be due to the Keypad mounting location, the room conditions, or the installation of a optional Mini
Prox Reader (ELK-M1PR).  The Keypad has an adjustment procedure which allows compensation for these conditions.

1. Press and hold the "

 * 

" key, followed by the F5 key .  HOLD BOTH keys pressed for 5-10 seconds or until the LCD displays

       

Exit when done. F1 Set Addr.   

(This is Keypad setup mode)

NOTE: This mode may also be accessed by removing  power from the keypad (unplugging the data bus cable) and then
applying power while holding any key pressed.

2. Press the F2 key and the LCD will display:    

Temperature Degrees F = XX.X  

(This is the current temperature)

3. Use the UP or DOWN arrow keys to adjust the current temperature display until it approximates the desired setting.  Each press of

the arrow keys changes the setting by approximately 3 tenths of a degree (00.3)  It may not be possible to end up exactly on an even
temperature setting.

4. Press the Exit key twice do return back to the regular operation mode.