ELK-MM220 HOOK-UP DIRECTIONS
The ELK-MM220 has been factory programmed with a sample application as labeled on
the unit, for other applications it must be reprogrammed before installation. The Program
Development Kit (ELK-MK400S) is required to re-program the ELK-MM220 if desired. The Develop-
ment Kit contains software and programming instructions needed to program the ELK-MM220. The
program is written using the Elk Magic Module Software and debugged by using the ELK-MM443
Magic Module that is included in the development kit. The program is then download into the ELK-
MM220 through a 5 conductor ribbon cable connected between the ELK-MM443 J1 connector and
the ELK-MM220 J5 connector. Note: If using the Clock/Calendar Module(ELK-MC100), temporarily
remove it to gain access to the ELK-MM443 J1 connector.
The ELK-MM220 has two digital inputs that switch from Low to High at approximately 2 Volts. Each
input is jumper selectable at J1 & J2 for an onboard 2K input resistor either pulled up to +12 Volts,
or pulled down to Ground. The ELK-MM220 has two form C relay outputs. Relay 2 is jumper
selectable using J3 to switch the output through a transistor (100mA max). Placing J3 to the OUT
position will disable Relay 2 and allow the Relay 2 COM terminal to be pulled to ground through a
transistor when activated. This setting handles up to 100mA of current and is intended for applica-
tions like flashing an LED. If more current or dry contacts are required then set J3 to IN and use the
Relay 2 contacts, the transistor will be disabled.
Test the ELK-MM220 after downloading the program to ensure that it functions as desired. The
ELK-MM220 can be reprogrammed multiple times.
*The ELK-MM220S version is required if using Savoy Automation Software.
GND
To Input Circuitry
+12 VDC
2K
Normally Closed
Opens from
Ground
Input HookupTypes for IN1 and IN2
INx
2
OUTPUT
ELK-MM220
PROGRAMMER
1
NO COM NC
NO COM NC
IN1 IN2 NEG
+12V NEG
RELAY 2
RELAY 1
J1
J2
INPUT 2
SELECT
J3
+12V
GND
INPUT 1
SELECT
RELAY 2
OUT IN
J5
D4
D3
MM220
will see a
Low to Hi
when
Switch
Opens
J1 or J2
NEG
GND
Input
Jumper
is set to
+12V
GND
To Input Circuitry
+12 VDC
2K
Normally Closed
Opening switch will
trip this input
INx
MM220
will see a
Hi to Low
when
switch
Opens
J1 or J2
NEG
GND
Input
Jumper
is set to
GND
+2 to 12 Volts DC
GND
To Input Circuitry
+12 VDC
2K
Normally Open
Closes to
Ground
INx
MM220
will see a
Hi to Low
when
Switch
Closes
J1 or J2
NEG
GND
Input
Jumper
is set to
+12V
GND
To Input Circuitry
+12 VDC
2K
Normally Open
Closing Switch to
2 to 12 Volts DC
will trip this input
INx
MM220
will see a
Low to Hi
when
Switch
Closes
J1 or J2
NEG
GND
Input
Jumper
is set to
GND
+2 to 12 Volts DC
+12 Volt DC Power Supply
ELK-624 Recommended
+
-
N.O.
N.C.
ALARM
SWITCHES
12 VOLT
SIREN
(ELK-45)
+
-
IN1 is a Momentary Key Switch, IN2 is a Normally Closed Burglar Loop, Relay 1 is the Alarm Output, Relay 2 is the Status LED
1K
J3 is shown with
Relay 2 out of ciruit,
the COM terminal will
be pulled to ground
when output 2 is
activated
(100ma Max)
LED
RELAYS
ACTIVE
LEDS
+
-
+
-
+12V position pulls up
IN1 or IN2 through a
2K resistor
GND position pulls
down IN1 or IN2
through a 2K resistor
+
Example Hookup: ELK-MM220 used as a Single Zone Security System
JUMPERS J1, J2 ,J3 are
located under cover
MOMENTARY
KEY SWITCH