background image

ELK-M1XRFEG

Wireless Receiver and Input Expander

Compatible with many models of GE branded Wireless Sensors,

including other brands which comply with the GE protocol.

Refer to page 8 & 9 for listing of known compatible sensors.

INSTALLATION

MANUAL

L629  Rev. B  7/30/2012

PO Box 100

3266 US Hwy 70 West

Hildebran, NC  28637

828-397-4200   828-397-4415 Fax

http://www.elkproducts.com

IMPORTANT NOTE:

ELK-M1G and M1EZ8 Controls SHOULD have application firmware ver. 5.2.0 or higher

to be compatible with the M1XRFEG Receiver.  Refer to M1Dealer website for update 'flash' files.

The latest version of ElkRP Programming Software is required for programming.

TM

  GE is a registered trademark belonging to GE & United Technologies.

Содержание ELK-M1XRFEG

Страница 1: ...ev B 7 30 2012 PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com IMPORTANT NOTE ELK M1G and M1EZ8 Controls SHOULD have application firmware ver 5 2 0 or higher to be compatible with the M1XRFEG Receiver Refer to M1Dealer website for update flash files The latest version of ElkRP Programming Software is required for programming TM GE is a regis...

Страница 2: ...ng measures If using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is induced or eliminated Move the receiver away from the security control Move the antenna leads away from any wire runs to the security control Have the device or controller plugged into a different outlet so that it and the receiver are on different branch circuits If...

Страница 3: ...lmentdatagetsstoredinthecontrolpanel not in the receiver s This provides two advantages 1 Multiple redundant receivers can be deployed in a building and a transmitter only need be enrolled one time Even portable devices such as Keychain Remotes work perfectly regardless of which receiver picks up the transmission 2 And should a receiver ever become damaged or need replacement it is not necessaryto...

Страница 4: ...nnect terminals 12V A B and Neg from the receiver to the M1 s Keypad Data Bus terminals VKP Data A Data B Neg NOTE Refer to the M1 Installation Manual and the M1DBH information in this manual about proper connections of data bus devices with multiple homerun cables 3 Antenna Installation The receiver is supplied with two 2 antennas These should be installed into the top locations marked Antenna Du...

Страница 5: ...icity installers are encouraged to set the data bus address of the first M1XRF Receiver if there are multiple Receivers to the starting zone ID as depicted in Tables 1 1 and 1 2 NOTE ELK strongly recommends that the starting wireless zone number conforms to the numbering scheme shown in Tables 1 1 and 1 2 even though the actual data bus address of the M1XRF could be address 10 while the first grou...

Страница 6: ...he ELK key then press 9 or scroll up to display 9 Installation Programming Press the RIGHT arrow key to select this menu The Installer Program Code PIN must be entered to access this menu 2 Enter the Installer Program Code The default code is 172839 3 The first Installer Programming menu displayed will be Bus Module Enrollment 4 Press the RIGHT arrow key to select this menu Enrolling Bus Modules w...

Страница 7: ...g or the ElkRP Remote Programming software The following pages document the options and steps for programming from the keypad Transmitter RF Level Checking Signal Strength Wireless transmitters send multiple repeats or rounds of their data transmission packets to compensate for interfer ence weak signal etc The repeated packets are useful to the receiver in providing level checking signal strength...

Страница 8: ...set to YES to disable internal Reed Switch NO leaves the internal switch active OPTIONS WZnxxx 04 Option 2 set to YES to use a N C Switch on External Contacts NO to use a N O Switch Door And Window Transmitter GE part 60 688 95 or equivalent Enroll Process Press Test Button or Tamper Switch OPTIONS WZnxxx 03 Option 1 set to YES to disable internal Reed Switch NO leaves the internal switch active O...

Страница 9: ...o YES to swap the action of the Asterisk button from 4 to 6 Note Pressing Lock and Unlock together triggers the event assigned to Key 7 Pressing the Light and Asterisk together triggers the event assigned to Key 8 Door And Window Transmitter Resolution Products Part RE101 Enroll Process Press Test Button or Tamper Switch OPTIONS WZnxxx 03 Option 1 set to YES to disable internal Reed Switch NO leav...

Страница 10: ...567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 123456789012345678901234567890121234 2 Xmit Sel b Prgr Transmitter Opt r 1234567890123456789012345678901212345 1234567890123456789012345678901212345 1234567890123456789012345678901212345 1234567890123456789012345678901212345 1234567890123456789012345678901212345 1234567890123...

Страница 11: ... instead Effectively swaps Key 4 for Key 6 DOUBLE KEYPRESSES Pressing the Lock and Unlock buttons together momentarily will trigger the event assigned to Key 7 The M1 Default Event Value is 0000 or No default function Pressing the Light and Asterisk buttons together momentarily will trigger the event assigned to Key 8 The M1 Default Event Value is 0000 or No default function WZone 17 shown as exam...

Страница 12: ... 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless zones Cells marked RRF indicate bus addresses where ONLY a redundant M1XRF Receiver can be installed Cells marked H or RRF indicate bus addresses where either a M1XIN Hardwired Expander OR a redundant M1XRF Receiver can be installed Thes...

Страница 13: ...dr 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 128 Data Bus Addr 9 Zn 129 144 Starting Zn ID 145 Data Bus Addr 10 Zn 145 160 H or RRF Total Wireless Zones max 16 H or RRF H or RRF H or RRF H or RRF H or RRF H or RRF H or RRF H or RRF H or RRF H or RR...

Страница 14: ...113 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 10 M1XIN or Keypad Zones Bus Addr 13 M1XRF M1XIN or Redundant M1XRF NO M1XIN Expanders on these addresses Zones 1 16 Inputs on Main Panel Zones 17 32 Zones 33 48 Zones 49 64 Zones 65 80 Zones 81 96 Zones 97 112 Zon...

Страница 15: ...P Updates directory This is where RP looks for all update files 7 Click on the check box for Update If Reprogram or Rollback is displayed the firmware file is the same as OR older that what is in the control Reprogramming with the same firmware is a waste of time but was included for factory testing purposes Rollback is not recommended except under the guidance of Elk Technical Support After the f...

Страница 16: ...Page 16 M1XRFEG Installation Manual ...