APPLICATION:

The ELK-110 is ideal for residential and commercial 

alarm  applications.    It  combines  the  advantages 

of high quality voice messages with conventional 

siren and temporal code tone sounds.  It features 3 

input channels, bilingual voice messages, and many 

unique options.

Features or Specifi cations subject to change without notice.

Voice Driver

ELK-110 

v5

Instructions Printed On Inside

ELK-110 

v5

FEATURES:

•  Three Input Channels, Burglar, Fire, and CO

•  Siren only, Voice only, or combined

•  Bilingual Voice - English & Spanish

•  Temporal Coded Tones - ANSI standard  Audible 

Emergency Evacuation Signaling

•  Speaker Trouble Supervision

SPECIFICATIONS:

•  Nom. Operating Voltage: 10-14 Volts D.C.

•  Nom. Current Draw: 1.25 Amps (8 Ohm Spkr)

•  Min. Low Current Trigger: 10.5VDC

•  Sound Level: 122 db @1meter

•  Freq. Temporal 3=800Hz, Temporal 4=1000Hz

•  MilliMiser™  Current Drain 800 mA

•  Maximum Speaker Loading: 4 Ohms

•  Size: 2.75" X 4.0"  (70mm X 102mm)

06/11

With Siren & Temporal Coded Tones

* Now includes Carbon Monoxide Alarm *

With Siren & Temporal Coded Tones

OVERVIEW

The ELK-110 features pre-recorded alarm messages in 

English & Spanish and 3 alarm channels, 1 for Burglar, 1 for 

Fire, and 1 for Carbon Monoxide.  The siren/tones include 

High/Low Siren for Burglary, Temporal 3 Coded Tone for Fire, 

and Temporal 4 Coded Tone for Carbon Monoxide.  Jumper 

pins allow customization of options and features.

INPUTS

The ELK-110 has both positive 

(+BA)

 and negative 

(-BA) 

inputs for Burglary conditions, making it compatible with 

most Controls.  Tripping either channel causes a Burglary 

warning message and a loud high/low siren.  For Controls 

that provide steady and pulsing on their alarm outputs, the 

ELK-110 off ers 

ComboTrigger™ 

which can distinguish a pulse 

from a steady and automatically switch Burg to Fire.

+FA (FIRE)

 This input is positive (+) trip only, and features 

a Fire warning message and a Temporal 3 Coded Tone.  It 

is compliant with ANSI standard for Audible Emergency 

Evacuation Signaling.

+CO (Carbon Monoxide)

  This input is positive (+) trip only, 

and features a Carbon Monoxide warning message and a 

Temporal 4 Coded Tone.

FIRE (+FA)

 Override  Should the +FA input be activated while 

either the +BA or +CO Alarm channels are sounding, Fire will 

take priority and will override the other alarms. 

Caution: This ONLY functions on the +FA input.  Pulsing 

on the +BA or -BA to activate Fire WILL NOT OVERRIDE 

the +BA or +CO alarms.  If Fire priority override is desired, 

connect ONLY Positive (+) Steady output triggers to the 

three (+) inputs.  

VOICE  MESSAGES

Voice messages are spoken in English Only, or English 

followed by Spanish.  (See "Switch & Jumper Options").     

BA (Burglar) English:

Intruder, intruder, the authorities have been notifi ed, leave 

immediately. 

 Followed by high/low Alarm sound.  This 

repeats until trigger is removed.  {Spanish can be added 

by placing a shorting jumper on JP5}

FA (Fire) English: 

Fire, fi re, please evacuate the building.

  Followed by 

Temporal 3 Coded Tone.  This repeats until the trigger is 

removed. {Spanish can be added by placing a shorting 

jumper on JP5}

CO (Carbon Monoxide) English: 

Warning, Carbon Monoxide, please evacuate the building.

Followed by Temporal 4 Coded Tone.  This repeats until 

the trigger is removed.  {Spanish can be added by placing 

a shorting jumper on JP5}

OUTPUTS

SPEAKER

 - For connection of Alarm Speaker(s).  The lowest 

sustainable impedance is 4 Ohms.  

SPKR TRBL

 - (Speaker Supervision, see option JP8)  

The ELK-110 can monitor the SPEAKER Output and provide 

a switched low (pull to ground) on terminal "Out" when no 

continuity is detected (e.g. cut wire or removed speaker).  

A N/O or EOL resistor Control Zone may be connected as 

follows: Connect SPKR TRBL "NEG" terminal to the Zone 

Neg.  Connect SPKR TRBL "OUT" to the Zone Input.  The EOL 

resistor (if used) is connected across these inputs. 

* Supervision only detects total loss of continuity, it will not 

detect a dead short on the SPEAKER output. * 

Be sure to place a shorting jumper on JP8 and connect the 

RED (+12V) wire to a constant power source.

When the ELK-110 is active and sounding an alarm it may 

be possible for the SPKR TRBL output to inadvertently false 

activate.  This is normal due to the fact that speaker continuity 

cannot be measured while the siren is sounding.

SPECIAL FEATURES: 

•  MilliMiser™

 - option reduces current draw for controls with 

limited alarm output power

•  ComboTrigger™

 - option for single alarm output controls which 

have the option of steady for burglar and pulsing for fi re.

•  VolumeStep™

 - option starts the siren sounds at low volume and 