Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.

No responsibility is assumed by Eliwell for any consequences arising out of the use of this material.

   WARNING

UNINTENDED EQUIPMENT OPERATION

• 

Use appropriate safety interlocks where personnel and/or equipment hazards exist.

• 

Install and operate this equipment in an enclosure appropriately rated for its intended environment.

• 

Power line and output circuits must be wired and fused in compliance with local and national regulatory requirements for the rated 
current and voltage of the particular equipment.

• 

Do not use this equipment in safety-critical machine functions.

• 

Do not disassemble, repair, or modify this equipment.

• 

Do not mount devices in extremely damp and/or dirt-laden areas.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

   WARNING

UNINTENDED EQUIPMENT OPERATION DUE TO CONNECTION

Signal leads (probes, digital inputs, communication and the signal electronic supply) must be routed separately from power and supply 
cables.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Probes have no connection polarity and can be extended using a regular bipolar cable (note that the extension of the probes affects the EMC 

electromagnetic compatibility of the instrument: pay extreme attention to wiring).

Содержание EZ-HT

Страница 1: ...Electronic controllers for refrigeration units EN EZ HT EZ MT EZ LT...

Страница 2: ...menu items Increases values Press for at least 5 sec Activates the Manual Defrost function DOWN Press and release Scroll menu items Decrease values Press for at least 5 sec Function can be configured...

Страница 3: ...tive Flashing delay protection or activation blocked Off otherwise Defrost LED Permanently on defrost active Flashing activated manually or from DI Off otherwise Allarm LED Permanently on alarm active...

Страница 4: ...9 mm 2 32 in ELECTRICAL CONNECTIONS DANGER HAZARD OF ELECTRIC SHOCK EXPLOSION OR ARC FLASH Disconnect all power from all equipment including connected devices prior to removing any covers or doors or...

Страница 5: ...0 28 C 0 5 0 6 4 42 5 31 N m lb in 0 25 2 5 22 13 DANGER POTENTIAL OF OVERHEATING AND FIRE Do not use with loads other than those indicated in the technical specification Do not exceed the maximum per...

Страница 6: ...lar equipment Do not use this equipment in safety critical machine functions Do not disassemble repair or modify this equipment Do not mount devices in extremely damp and or dirt laden areas Failure t...

Страница 7: ...supply 230 Vac 9 10 Pb1 probe 10 11 Digital input TTL TTL input 1 N L 2 3 6 7 8 9 10 D I Pb1 4 5 11 Pb2 evaporator thermostat TTL Power Supply EZ MT EZ LT TERMINALS 1 3 Fans relay 2 3 Compressor rela...

Страница 8: ...ut relay Refer to the label on the device Fire resistance category D Software class A NOTE check the power supply specified on the instrument label contact our Sales Office for power supply and relay...

Страница 9: ...eys Dimensions Front 76 4x35 mm 3 01x1 38 in depth 59 mm 2 32 in without terminals Terminals Screw terminals for wires with cross section of 2 5 mm2 13 AWG Connectors TTL for connection to Copy Card m...

Страница 10: ...uited open Displaylabel E1 Alarmiconpermanentlyon Disablemax minalarmcontroller Compressoroperationbasedon parametersOntandOFt Checkprobetype par H00 Checkprobewiring Replaceprobe E2 Pb2probe inoperab...

Страница 11: ...e alarm if LAL is negative Set LAL Set if HAL is negative Set HAL Set Setpoint LAL AFd Off Setpoint HAL AFd Setpoint LAL AFd Setpoint HAL AFd Setpoint LAL AFd HAL AFd LAL AFd HAL AFd Label Description...

Страница 12: ...gh all the folders in the menu AL alarms folder only visible if an alarm is active SEt Setpoint setting folder Pb1 probe 1 Pb1 folder PB2 probe 2 Pb2 folder EZ MT EZ LT models only folder displayed if...

Страница 13: ...ended when using the card for the first time NOTE the Fr parameter deletes all data present This operation cannot be cancelled Download ConnecttheCopycardwhentheinstrumentisswitchedoff Atpower on data...

Страница 14: ...if Ont 0 and OFt 0 it operates in Duty Cycle mode min 0 250 15 15 15 OFt Controller switch off time in the event of a inoperable probe if OFt 1 and Ont 0 the compressor stays off permanently OFF if O...

Страница 15: ...parameter dtY 3 Not used num 0 3 1 1 1 dOH Defrost start delay time after request min 0 59 0 0 0 dEt Defrost time out determines the maximum defrost duration min 1 250 20 25 25 dSt Defrost end temper...

Страница 16: ...tion to the setpoint 0 Absolute value 1 Relative value flag 0 1 0 0 0 AFd Alarms activation differential C F 1 0 50 0 2 0 2 0 2 0 HAL Temperature value intended either as distance from setpoint or as...

Страница 17: ...3 1 1 1 dAd Digital input activation delay min 0 255 0 0 0 OSP Temperature value to be added to the Setpoint if reduced set enabled Economy function C F 30 0 30 0 0 5 0 5 0 5 LOC Lock Setpoint change...

Страница 18: ...s 10 F flag 0 1 0 0 0 ddd Selects type of value to display 0 Setpoint 1 Probe Pb1 2 Probe Pb2 3 Not used num 0 3 1 1 1 H00 Probe type selection 0 PTC 1 NTC num 0 1 1 1 1 H11 Configuration of digital i...

Страница 19: ...annot accept liability for any damage resulting from its use The same applies to any person or company involved in preparing and editing this document ELIWELL CONTROLS SRL reserves the right to make a...

Страница 20: ...0437 989 066 www eliwell com Technical Customer Support T 39 0437 986 300 E Techsuppeliwell schneider electric com Sales T 39 0437 986 100 Italy T 39 0437 986 200 other countries E saleseliwell schnei...

Отзывы: